LOCATION OF FIREBOX
Carefully select the best location for installation of your vent-free fi rebox. The following factors should be taken
into consideration.
• Clearance to side wall, ceiling, woodwork, and windows. Refer to “CLEARANCES and HEIGHT REQUIREMENTS”
section below and on pages 8 and 9. Minimum clearances to combustibles
must be maintained.
• Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air registers for forced
air furnaces/air conditioners, windows, or doors.
• Installation must provide adequate ventilation and combustion air.
• DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM.
• Location should be out of high traffi c or windy or drafty areas.
• DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS
ARE LESS THAN 36" FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent-free fi rebox or restrict the fl ow of combustion and ventilation air.
• Minimize modifi cations to existing construction.
Refer to Figure 2
for location suggestions.
• Do not install in the vicinity where gasoline or other fl ammable liquids may be stored. The vent-free fi rebox must be
kept clear and free from these combustible materials.
Figure 2 - Suggested Firebox Locations