CLEARANCES
AND
HEIGHT REQUIREMENTS
Sidewall and ceiling clearances:
The
sides
of the fireplace opening must be
at least 16"
from any combustible wall.
The
ceiling
must be
at least 42"
from the top of the fireplace opening.
Figure 4 - Sidewall and Ceiling Clearances
The dimensions shown in Figures 4 through 12 and defined in the fireplace manufacturer's
instructions are
minimum clearances
to maintain when installing this heater. Left and
right clearances are determined when facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances, as specified by
the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.