REPLACEMENT PARTS LIST 

REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. 

 Accessories                                                

       

Flex Connector                                        Flexcon 30             All Models

       

Wall Switch Kit                                         MVWS                    Milli-volt only

       Wall Thermostat Kit                                 MVWTS                 Milli-volt only
       Hand Held Remote                                  RCM                       Milli-volt only
       Hand Held Thermostat Remote               RCT                       Milli-volt only
       Remote Receiver Cover Ember               RRCE                     All Models
       Remote Receiver Cover Metal                RRCM                    All Models 
       Thermostat Sensor Kit                             TS                          All Models 

DEB20

Item      Description                              Qty        Natural         Propane            Natural         Propane

Common Parts

    1       Piezo Ignitor                                1         14D0503        14D0503          14D0503        14D0503
    2       Piezo Wire                                   1         00K0632        00K0632           00K0632        00K0632                
    3       Front Burner                                1        44D0020K      44D0020K       44D0019K      44D0019K
    4       Rear Burner                                 1        44D0035K      44D0036K       44D0081K      44D0082K

Manual Control

   

5       Control Valve                               1         30D0201        30D0202          30D0201        30D0202               

    6       Control Valve Nut                        1         00F0586        00F0586           00F0586        00F0586                
    7       Valve Regulator                           1         24D0305        24D0306          24D0305        24D0306               
    8       Front Burner Injector                   1         44D0200        44D0202          44D0204        44D0206               
    9       ODS Pilot Assembly                    1         26D2529        26D2530          26D2529        26D2530               
   10      Control Knob                               1         18D0603        18D0603          18D0603        18D0603               
   11      Rear burner Injector                    1         44D0201        44D0203          44D0205        44D0207

Milli-Volt Control / Thermostat Control 

    5       Control Valve                               1         14D0467        14D0468          14D0467        14D0468
    8       Front Burner Injector                   1         44D0208        44D0210          44D0212`        44D0214
    9       ODS Pilot Assembly                    1         14D0473        14D0474          14D0473        14D0474
   10      Control Knob                               2         18D0603        18D0603          18D0603        18D0603
   11      Rear burner Injector                    1         44D0209        44D0211          44D0213        44D0215
   12      On/Off Switch                              1         32D0232        32D0232          32D0232        32D0232
   13      Thermostat Sensor                      1         26D3314        26D3314          26D3314        26D3314

Hi/Lo Remote Control

    5       Control Valve                               1         14D0467        14D0468          14D0467        14D0468
    8       Front Burner Injector                   1         44D0208        44D0210          44D0212        44D0214
    9       ODS Pilot Assembly                    1         14D0473        14D0474          14D0473        14D0474
   10      Control Knob Assembly               2         18D0603        18D0603          18D0603        18D0603
                Control Knob Adapter               2        44D0221K      44D0221K       44D0221K      44D0221K
                HI/LO control Knob Adapter     2        44D0220K      44D0220K       44D0220K      44D0220K              
   11      Rear burner Injector                    1         44D0204        44D0211          44D0213        44D0215

BURNER ASSEMBLY 

DEB24/DEB30

Summary of Contents for DEB20

Page 1: ...o not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric...

Page 2: ...Control 21 Milli Volt Thermostat Control 21 Hi Lo Control 21 Electrical Wiring Milli volt 22 Connecting Remote Receiver 23 Installing Thermostat Sensor 23 Operation of Thermostat Sensor 25 Log Placem...

Page 3: ...reference IMPORTANT Read these instructions carefully before installing or trying to operate this vent free gas heater 1 Due to high temperatures the appliance should be located out of traffic and aw...

Page 4: ...isappear with continued use 20 Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 percent for each 1 000...

Page 5: ...Hand held Remote with receiver GETTING STARTED Carefully inspect the contents for shipping damage If any parts are missing or damaged immediately inform the dealer from whom you purchased the applian...

Page 6: ...20PT THERMOSTAT 28 000 20 000 DEB24PT THERMOSTAT 38 000 30 000 DEB30PT THERMOSTAT 38 000 30 000 NATURAL GAS NOTE An external regulator is required to reduce supply pressure to a maximum of 10 1 2 W C...

Page 7: ...o desired flame height Milli Volt and T Stat control has four 4 positions OFF All gas to the gas logs is shut off at the valve IGN Valve position to light maintain a standing pilot ON Valve position t...

Page 8: ...ces installed in that space An unconfined space is defined as a space whose volume is not less than 50 cubic feet per 1 000 BTU per hour 4 8 m3 per kw of the aggregate input rating of all appliances i...

Page 9: ...ion would be based only on the room with the heater BTU Hr 151 2 x 12 x 8 50 GENERAL INSTALLATION INFORMATION Figure 1 Example of a Large Room with 1 2 Wall Divider Counter Fireplace x 1000 x 1000 528...

Page 10: ...ure for Gas Fired Decorative Type Unvented Room Heaters per IAS Requirement No 2 97 ANSI Z21 91 2001 typically referred to as a Universal Firebox as long as firebox hearth dimensions meet the minimum...

Page 11: ...or bottom surface of the unit Refer to Table The log set should be placed against or as near as possible to the rear wall of the fireplace firebox Depth of fireplace firebox Refer toTable Figure 3 Ref...

Page 12: ...n in Figures 4 through 12 and defined in the fireplace manufacturer s instructions are minimum clearances to maintain when installing this heater Left and right clearances are determined when facing t...

Page 13: ...ese minimum clearances you must operate the heater with chimney flue damper open Refer to Installing Vented Applications found on page 18 HEAT RESISTANT REQUIREMENTS FOR SAFE INSTALLATION MATERIAL MEA...

Page 14: ...ed Observe profile side elevations shown in Figure 7 page 15 elevations shown in Figure 9 page 16 8 to less than 12 Install hood and observe profiles shown Install hood and observe profiles shown in F...

Page 15: ...the wall a maximum of 21 2 at a minimum of 14 above the opening and a maximum of 6 at a minimum of 201 2 above the opening Example A mantel may project from the wall a maximum of 21 2 at a minimum of...

Page 16: ...um of 10 at a minimum of 28 above the CLEARANCES AND HEIGHT REQUIRMENTS Figure 10 is an example of an unsafe mantel installation This mantel projects 4 at 8 above the opening exceeding the maximum acc...

Page 17: ...he top surface of carpeting tile etc See Figure 11 OR The gas log heater may be installed nearer to the floor if a minimum of 14 of noncombustible material such as slate or marble is installed between...

Page 18: ...leaning performed annually after installation Seal any fresh air vents or ash clean out doors located on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat resista...

Page 19: ...logs function as a system If the fireplace is spilling into the room check with a match or a smoke stick reposition the damper clamp until a positive draft is obtained by opening the damper If negati...

Page 20: ...at the Pressure Tapping Point May Be Installed Use new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen...

Page 21: ...place tubing to pressure gauge over test point Use test point OUT closest to control knob After taking pressure reading be sure and turn captured screw clockwise firmly to re seal Do not over torque...

Page 22: ...t one wire to TP TH and one wire to TH or connect the wall switch thermostat to the two male 0 25 terminals on the left side of the unit The color of the wires does not matter Figure 19 Wiring Diagram...

Page 23: ...unit See Figure 20 7 Attach remote receiver with velcro pads Control switch must face forward NOTE Heat reduces battery life You can protect the receiver and extend battery life by mounting the recei...

Page 24: ...sting wiring harness with two 2 0 250 male spade terminals for remote or t stat option See Figures 23 and 24 7 Install knob to shaft of t stat sensor See Figure 23 8 Place thermo bulb in front of the...

Page 25: ...NTACTS READING TERMINALS SHOULD BE A COMPLETE 2 3 CLOSED MINIMUM SYSTEM 175 B THERMOPILE 1 2 OPEN MINIMUM OUTPUT 500 CHECKING SYSTEM OPERATION The milli volt system and individual com ponents may be c...

Page 26: ...r five ceramic fiber logs Do not handle these logs with your bare hands Always wear gloves to prevent skin irritation from ceramic fibers After handling the logs wash your hands gently with soap and w...

Page 27: ...ilot flame If the pilot flame does not touch the thermocouple then the main burner cannot function reliably See Figures 29 and 31 for incorrect shape of pilot flame MILLI VOLT CONTROL AND THERMOSTAT C...

Page 28: ...oper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but ma...

Page 29: ...or s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the kno...

Page 30: ...ping 7 With the control knob pushed in push and release the piezo ignitor button to light the ODS pilot The pilot is located on the left side of the heater behind the middle log and on the back of the...

Page 31: ...in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting off the gas while the probe is wa...

Page 32: ...t is located on the left side of the heater behind the middle log and in front of the rear log If piezo ignitor does not light the pilot refer to Match Lighting Instructions page 33 8 Hold the gas con...

Page 33: ...take holes clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern and log...

Page 34: ...2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing 5 Replace ignitor cable 6 Replace piezo ignitor 1 Ventilate room Stop using odor causing products whi...

Page 35: ...clogged burner orifices 1 LP regulator shut down due to inlet pressure too high REMEDY 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 Fully open...

Page 36: ...MENT PARTS Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury WARNI...

Page 37: ...urner Injector 1 44D0200 44D0202 44D0204 44D0206 9 ODS Pilot Assembly 1 26D2529 26D2530 26D2529 26D2530 10 Control Knob 1 18D0603 18D0603 18D0603 18D0603 11 Rear burner Injector 1 44D0201 44D0203 44D0...

Page 38: ...4D1010K 44D1000K 44D1005K 3 Front Log 1 44D1012K 44D1002K 44D1007K 4 Left Log 1 N A 44D1003K 44D1008K 5 Top Log 1 44D1013K 44D1004K 44D1009K REPLACEMENT PARTS LIST Failure to position the parts in acc...

Page 39: ...44D0060 39 NOTES...

Page 40: ...in accordance with the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with t...