CLEARANCES and HEIGHT REQUIREMENTS
Figure 6 - Measuring Heat Resistant Material for Mantel
Heat resistant material (minimum requirements) with wooden mantel or other combustible projection:
To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat resistant
material shown in
Figure 6,
then refer to Table B.
TABLE B - Heat Resistant Material Heights and Mantel Location
HEAT RESISTANT REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL,
MATERIAL SHELF OR OTHER COMBUSTIBLE PROJECTION
MEASUREMENT
DEB20 DEB24 and DEB30
12" or more Hood not required. Observe profiles (side Hood not required. Observe profile (side
elevations) shown in
Figure 7, page 15.
elevations) shown in
Figure 9, page 16.
8" to less than 12" Install hood and observe profiles shown Install hood and observe profiles shown
in
Figure 8, page 15
;
OR
extend heat in
Figure 7, page 15
;
OR
extend heat
resistant material to at least 12" and observe resistant material to at least 12" and observe
profiles shown in
Figure 7, page 15.
profiles shown in
Figure 9, page 16.
Less than 8" Extend heat resistant material to at least Extend heat resistant material to at least
8", install hood and observe profiles shown 8", install hood and observe profiles shown
in
Figure 8, page 15
;
OR
extend heat in
Figure 7, page 15
;
OR
extend heat
resistant material to at least 12" and observe resistant material to at least 12" and observe
profiles shown in
Figure 8, page 15.
profiles shown in
Figure 9, page 16.