background image

21

CWC Series Woodburning Fireplace

87D1504

Model Number

Description

Component

(Chimney Components con't.)

  Square Chase Termination 

Square chimney cap used to terminate chimney 

SLTS8  

 

 

   

through chase. Includes adapter. 

 

 

 

  

   

(Flashing material)

  Adapter Kit 

Required to unite 3-wall chimney with S20BR,  

S20UB 

 

 

   

S20BT, S20BW Traditional Top Housing

  Chimney Support 

Used to support the chimney at each 30' of  

TCS8A 

 

 

   

of vertical height above the hearth and 

 

 

 

 

   

at every 6' of inclined chimney run. 

 

 

 

 

   

Each support adds 2

Z\x

" to chimney length.

  Firestop 

Required at each floor level and attic on 

FS2A (8" straight flue)   

   

multi-story installation.   

FS6A (8" 30° inclined    

   

 

 

flue)

  Radiant Shield 

Used as an alternate to FS2A firestop to 

RS-8A  

 

 

   

reduce the clearance from the chimney to 

 

 

 

 

   

combustible framing. With 16" center lines.

  Attic Insulation Shield 

Used to prevent attic insulation from  

FS2100-HT 

 

 

  (3-wall) (CF-11) 

contacting the chimney system.

  Canada

  Chimney Collar Enclosure 

Installs on the "over the chimney collar" of the  

CCE-SK 

   (SK8) 

fireplace; provides outside air to assist in cooling 

   

the chimney system.  

  Attic Insulation Shield 

Used to prevent insulation from coming in 

AIS-SK  

  (SK8) 

contact with the chimney system. 

  SK8 Chimney Sections 

Used to build chimney systems exposed above      

SK818CAN (1

Z\x

' Long)  

   

roof.          

                                            

SK84CAN (4' Long)

  45˚ Chimney Elbows 

Provides 45° offset and return. For Canadian          

SK845/2 

  

   

installations only. For use with SK8 chimney only.  

   

(Maximum use of 2, or 1 pair.)

  Chimney Sections 

Used to build chimney systems exposed above 

8" flue  

 

 

  (3-wall) 

roof. 

 

  818CAN (1

Z\x

' Long)   

   

 

 

  84CAN (4' Long)

  Attic Insulation Shield 

Used to prevent attic insulation from  

FS2100-HT 

 

 

  (3-wall) (CF-11) 

contacting the chimney system.

Summary of Contents for CWC400

Page 1: ...se in U S Canada Underwriter s Laboratories Report No MH7603 DO NOT DISCARD THIS MANUAL Retain for future use 87D1504 12 09 Rev 4 FP583A WMC 12 18 98 CWC Series Woodburning Fireplaces Homeowner s Inst...

Page 2: ...HSC in combination or assembly with a MHSC fire place system notwithstanding any indepen dent testing laboratory or other third party ap proval of such component parts or accessory Any such action may...

Page 3: ...203mm 3 6 9 1 4 m m Fig 2 CWC500 Series specifications and framing FP592A CWC500 Series Woodburning Fireplace Circulating Model FP590A WMC36 SPECS 1 28 99 djt B 1 6 m m Z x 13mm Z x 36 914mm 35Z v 895...

Page 4: ...Outlet Grille Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 pieces Inlet Grille Outside Air Cover Plate Electrical Access Gas Line Access both sides Nai...

Page 5: ...1 0 0 1 0 31 60 0 1 0 1 0 34 65 0 0 2 0 0 37 70 1 1 0 1 1 41 77 0 0 1 1 1 45 83 0 1 2 0 1 47 87 0 0 0 2 1 51 94 0 1 1 1 1 53 98 0 0 3 0 1 56 103 0 1 0 2 1 59 108 0 0 2 1 1 62 113 0 1 3 0 1 64 117 0 0...

Page 6: ...2 609 mm above the peak of the roof but never less than 3 914 mm in height above the highest point where it passes through the roof 2 If a horizontal distance from the chimney to the peak of the roof...

Page 7: ...u live in a cold climate it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible Insulate base of fireplace with a noncomb...

Page 8: ...tions Read all instructions before beginning installation Fol low instructions carefully The SCVS speed control may be used as an alternate wall switch in lieu of the single pole Listed 1 5 Amp 120V s...

Page 9: ...bows Use the 30 Offset Elbow table on Page 5 to determine proper offset and parts required Each offset requires two 2 elbows The second elbow is equipped with support straps It is very important to in...

Page 10: ...FP551 WF551 BR BC 9 29 97 See Fig 12 See Fig 12 Existing Ceiling Joists Ceiling New Framing Members Chimney Hole Fig 12 Ceiling chimney hole sizes necessary for installing firestop spacer Size of Chim...

Page 11: ...y snap together Once sections are snap locked in place it is extremely difficult to get them apart Make sure the pipe is firmly snapped and locked together as each pipe section is mounted When install...

Page 12: ...framing hole Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails Attic shields are not required at the roof Continue Installing Pipe to Complete Run C...

Page 13: ...c tions all pipes should extend Installing Top Housing or Termination Follow the installation instructions provided with the chimney termination you have selected Installing Chimney In a Chase Refer t...

Page 14: ...Wall Shield Model SP40 or a specifically built wall shield described below The special wall shield design described in Figure 19 is an alternate method of adding protection to side walls and can be u...

Page 15: ...om manufacturer of the material Fac tors are related by the formula K 1 R T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R v...

Page 16: ...d material per inch material Example of Determining Hearth Extension Equivalents To determine the thickness required for any new mate rial Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in ne...

Page 17: ...en the pipe and tube Note Gas pipe should not come in contact with any wood structures until it has reached a point at least one 1 inch away from fireplace side NOTE When installing an ANSI Z21 11 2 v...

Page 18: ...D0131 26D0131 5 Damper Knob Wood 7536177 7536177 6 Firebrick Left Side 3041104 3034102 7 Firebrick Back 3030102 3034104 8 Firebrick Right Side 3041105 3034103 9 Firebrick Hearth 3041103 3034105 10 Scr...

Page 19: ...d the coverage provided by the owner s insurance Accessories Contact your Monessen distributor or dealer for finishing Mantels available in a wide selection of styles Glass Door Optional Bi Fold door...

Page 20: ...e chimney cap used to PLTSK8 SK8 terminate chimney through a chase Includes adapter Flashing not included Chase Top Housing Square chimney cap used to terminate chimney SLTSK8 SK8 through a chase Incl...

Page 21: ...m the chimney to combustible framing With 16 center lines Attic Insulation Shield Used to prevent attic insulation from FS2100 HT 3 wall CF 11 contacting the chimney system Canada Chimney Collar Enclo...

Page 22: ...22 CWC Series Woodburning Fireplace 87D1504...

Page 23: ...re dif ferentials produced by wind Broken glass components Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local b...

Page 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...