2
3
"Warning: If not installed, operated and maintained in accordance with the manufacturer’s
instructions, this product could expose you to substances in fuel or from fuel combustion which
can cause death or serious illness and which are known to the state of California to cause cancer,
birth defects or other reproductive harm. Also, operation, installation and servicing of this product
could expose you to airborne particles of glass wool fibers known to the state of California to
cause cancer through inhalation."
The gas fireplace must be installed and serviced by a qualified installer to conform with local codes. In the
absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig.
The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Pressures in excess of 1/2 psig will cause damage to the control valve and may cause damage to the shutoff
valve.
Model BBV400NV (Natural Gas):
Maximum Input: 18,000 BTU Per Hour
Minimum Inlet Gas Supply Pressure: 4.5 inches water column
Maximum Inlet Gas Supply Pressure: 7 inches water column
Manifold Pressure Under Flow Conditions: 3.5 inches water column
Notice: This appliance operates with a yellow, smoky flame. When properly adjusted according
to these instructions, small amounts of carbon (soot) will be deposited on the outlet section of
the air terminal and possibly on surrounding structure. If not properly adjusted and operated
according to these instructions, carbon (soot) will accumulate in larger quantities on the air
terminal and surrounding structure and objects.
Do not attempt to operate the burner at an input rate other than that given by the flame adjustment valve.
Illustrations throughout these instructions reflect typical installations and are for design purposes only. Actual
installation may vary slightly due to individual design preferences. However, minimum and maximum clearances
must be maintained at all times. The illustrations and diagrams in these instructions are not drawn to scale.
Any additions, changes or conversions required in order for the appliance to satisfactorily meet the application
needs must be made by a distributor or dealer using factory specified and approved parts.
This product is manufactured to use natural gas. A natural gas unit can be converted to use propane, but ONLY
if converted by a qualified service technician and ONLY if the Natural Gas to Propane Gas Conversion Kit is
used.
If any assistance is required during installation, please contact your local dealer or the Customer Service
Department.
For Massachusetts Residences Only:
• This product must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts. Flexline installation must not exceed 36 inches.
I
MPORTANT
I
NFORMATION
53D9015. Rev 1 03/03
Summary of Contents for BBV400NE