AVFLST Vent Free Fireplace

SIGNATURE COMMAND

®

 SYSTEM OPERATION

Intermittent/Standing  Pilot  Setup  (Default  intermit-

tent)

1.  Holding the ON button on the Command Center while 

turning on the master switch will toggle between stand

-

ing pilot and intermittent pilot.

2.  After the above operation, one beep (for standing pi

-

lot) or two beeps (for intermittent pilot) will be given as 

confirmation.

Six-hour Safety Shutdown Option (Default ON)

1.  The system comes preset from the factory with a six (6) 

hour  shutdown  from  its  last  command  of  operation. 

This is done to prevent the fireplace from continuing to 

operate if unattended. You may disable this feature if 

you wish.

NOTE:

 By disabling this feature, your fireplace may con

-

tinue to operate unattended.

2.  When  the  master  switch  is  in  the  ON  position  (“-”), 

pressing  the  ON  button  and  the  OFF  button  on  the 

Command Center simultaneously will toggle between 

enabling and disabling the six-hour shutdown option.

3.  After the above operation, one beep (for enabling the 

six-hour shutdown option) or two beeps (for disabling 

the six-hour shutdown option) will be given as confirma

-

tion.

Remote Transmitter Learn Function (Default OFF)

1.  The RF receiver button located on the Control Board 

must be in the on position before the learn function can 

begin. Use paper clip to depress button. One beep for 

RF receiver ON or two beeps for RF receiver OFF will 

be given as confirmation. Refer to Figure 17 for location.

2.  After the RF receiver is on, holding the OFF button on 

the Command Center while turning on the master switch 

will activate the learn function for the transmitter.

3.  After the above operation, two beeps will be given and 

the green LED on the Command Center will flash for 

10 seconds.

4.  During  the  10  seconds,  press  the  OFF  button  on  a 

transmitter to learn. Another two beeps will be given 

to confirm a successful learning. Refer to transmitter 

instructions for remote operations.

Shutting Off the Standing Pilot (Temporary Shut Off)

To shut off the standing pilot for service or summer shut 

down,  press  and  hold  the  ON  button  on  the  Command 

Center for 3 seconds when the master switch is in the ON 

position (“-”) and the main burner is off.

Note

:  Pilot  will  resume  the  next  time  system  is  turned 

on.

Key Combinations for System Settings

NOTE: 

When On/Off wall switch is used, it must be in the 

On position to perform all system setups.

FUNCTION

OPERATION

DEFAULT SETTING

Intermittent/Standing Pilot 

Setup

Hold the ON 

é

 

button while turning the master switch

 

(It will beep once for standing pilot, twice for intermittent pilot.)

INTERMITTENT 

PILOT

Standing Pilot 

Temperature Shutoff

Hold the ON 

é

 

button for 3 seconds (when the master switch on 

the main burner is off.)

RF Remote Receiver

 

ON/OFF

Push the RF receiver ON/OFF button on the control board.

 

(It will beep once for On and twice for OFF.)

RF OFF

Learn Remote

 

Transmitter

Hold the OFF 

ê

 button while turning on the master switch

 

(Listen for two beeps, then press any button on the remote.)

6-Hour Safety

 

Shutdown Setup

Press the ON 

é

 button and OFF 

ê

 button simultaneously

 

(It will beep once for ON, twice for OFF.)

ON

SIGNATURE COMMAND

®

 SYSTEM FUNCTION SETTINGS

Summary of Contents for AVFLST42NTSC

Page 1: ...ght any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supp...

Page 2: ...ncombustible facing installation 10 Connect the gas 11 Check gas pressure 12 Gas pressures 12 ELECTRICAL INSTALLATION 13 Wiring junction box 13 FINAL INSTALLATION 15 Installation of air deflection gla...

Page 3: ...rviced as it may not be operating properly 10 The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 l NFPA54 11 This unit complies w...

Page 4: ...g 3 5 kPa 23 The appliance must be isolated from gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to...

Page 5: ...FUEL MAX INPUT BTU h MIN INPUT BTU h ORIFICE SIZE AVFLST42NTSC NAT 37 000 24 500 2 20 mm AVFLST42PTSC LP 36 000 28 500 55 GAS PRESSURES NATURAL PROPANE LP Inlet Minimum 5 0 w c 11 0 w c Inlet Maximum...

Page 6: ...nimum Rough Framing Height 32 813mm Minimum rough opening depth for 5 8 wall thickness 12 305mm Interior wall installation Exterior wall installation Minimum Rough Framing Width 44 1118mm 44 1118mm Wa...

Page 7: ...removed from under the unit 2 Install following the instructions found in this manual 3 Field wire main power supply to junction box Refer to the Electrical Installation section page 13 Electrical co...

Page 8: ...indow or other combustibles Refer to Clearance and Height Requirements section on Page 9 Minimum clearances to combustibles must be maintained Location must not be affected by drafts caused by kitchen...

Page 9: ...instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire hazard Floor Clearance The fireplace may be installed directly on a combustible floor or a...

Page 10: ...materials which do not protrude beyond the face NONCOMBUSTIBLE FACING INSTALLATION CAUTION The noncombustible wall board supplied with this unit can be damaged if dropped or struck Handle with care 1...

Page 11: ...T Loosen the pipe adapter on the flex tube before installing to the system piping Always use an external regulator for all propane LPG heat ers only to reduce the supply tank pressure to a maximum of...

Page 12: ...and then place tubing to pressure gauge over test point Use test point A closest to gas inlet If the pressure is not within the range listed for your gas type turn the valve reg ulator until it is wi...

Page 13: ...ld only be performed by a qualified licensed electrician Main power supply must be turned off before connecting to the main electrical power supply or performing service WARNING Electrical Grounding I...

Page 14: ...lve Black Yellow Thermocouple Pilot Thermocouple Module Orange Red Plug in Connector A A C MODULE TO JUNCTION BOX IN FIREPLACE PLUG IN CONNECTOR A WHITE BLACK GREEN WHITE BLACK Opt Blower Hearth Light...

Page 15: ...er needs to burn cleanly This may cause sooting 1 Spread fireglass evenly in one layer over the entire floor and burner It is important to not have the fireglass too thick on ported area single layer...

Page 16: ...supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not function by hand do no...

Page 17: ...ep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pil...

Page 18: ...and pull out to remove battery door 2 Install the batteries as indicated on Command Center 3 Close battery door by snapping in place 4 When the four 4 batteries are installed the system will operate...

Page 19: ...er is on holding the OFF button on the Command Center while turning on the master switch will activate the learn function for the transmitter 3 After the above operation two beeps will be given and th...

Page 20: ...mmands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings will resume To reset change to the desired settings and...

Page 21: ...tment arrows The blue LED backlight lights up for 8 seconds when any of the touch buttons is pressed The menus include TIMER THERMO LIGHT and AUX The adjustment arrows include ON up and OFF down Their...

Page 22: ...tory In the event of activation or interference from other nearby transmissions change the code using the following procedures learn function must be performed af ter changing the code 1 Press the ON...

Page 23: ...ld the TIMER button for 3 seconds or b Use the OFF down buttons to decrease the Set Time to zero or c Slide down on the arrow buttons to exit TIMER mode and shut off the fireplace Thermostat Mode Figu...

Page 24: ...n but tons become flame height controller again 5 When the light button is flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the l...

Page 25: ...hen the ambient temperature is less than 40 de grees Fahrenheit the LCD will display LO and NO SIGNAL will be sent to turn on the appliance All functions still remain the same for both Manual Mode and...

Page 26: ...tteries should be changed every six 6 months Appliance does not come on The transmitter did not sync with the receiver Make sure the transmitter has synced to the receiver There will be two audible be...

Page 27: ...d Lo and Off and cycles through the color selection Color selection options Using the color slection button you can choose from ten 10 different lighting options 1 Color fade This selection will cycle...

Page 28: ...r intake holes Remove lint or particles with vacuum brush or pipe cleaners Failure to keep air intake holes clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect...

Page 29: ...ED control assembly in place See Figure 36 Turn flat and pull forward 5 Remove the two black LED connectors 6 From inside unit start at one end of the strip and begin to peel from base 7 Repeat with s...

Page 30: ...patterns Sooting and improper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemic...

Page 31: ...with ON OFF switches off Gas odor even when control knob is in OFF position Gas leak Locate and correct all leaks Control valve defective Replace control valve Burner does not light after ODS pilot i...

Page 32: ...onnected to the appliance Ensure that both the 3V IPI control module power supply as well as the LED power supply are securely plugged into the appliance junction box Faulty wiring Check appliance for...

Page 33: ...heck gas supply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage...

Page 34: ...e 6 2 20303043K Medium Dark Gray Stone 7 2 20303044K Medium Tan Stone 8 2 74D0718K Small Tan Stone 9 1 78D0141K Small Dark Gray Stone 10 2 74D0717K FIREBOX ITEM DESCRIPTION QTY PART NO 1 Bulb Top Ligh...

Page 35: ...14D0473 14D0473 5 Pilot Regulator not shown 1 14D0469 6 Control Box 1 80D0018 80D0019 7 Command Center 1 80D0005 80D0005 8 Injector 2 20305649 62D3005 9 Venturi 2 45D0600 20305775K 10 Flexhose w Shut...

Page 36: ...time Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dam...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...149 Cleveland Drive Paris Kentucky 40361 www monessenhearth com...

Reviews: