AVFLST Vent Free Fireplace
ELECTRICAL INSTALLATION
IMPORTANT:
Always check local building codes. This in
-
stallation must comply with local regulations as well as
the National Electric Code.
WIRING JUNCTION BOX
1. Before installing, wire the receptacle into an electrical
circuit. This should be done before framing the fire
-
place. Wire with minimum 60° C wire in accordance
with prevailing codes.
2. Junction box was installed at the factory. Remove the
external junction box cover by removing the screw
from the right side of the outside firebox wall.
3. The junction box cover has a factory installed “romex”
style strain relief connector. After connecting the wires,
route the wire leads through this connector.
WARNING!
Electrical connections should only be performed by
a qualified licensed electrician. Main power supply
must be turned off before connecting to the main
electrical power supply or performing service.
WARNING!
Electrical Grounding Instructions:
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three prong receptacle.
WARNING
!
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
For vent free Signature Command
®
Systems, the unit will
continue to burn during power loss only with batteries
installed. Without power, the unit will shut down without
batteries installed but can be started with fresh batteries
installed in the Command Center.
Figure 12.
Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
Junction Box
Factory Supplied
Not Supplied
120V AC
60Hz