Symptom 

Problem 

Remedy

 

1)

 

When opening the tap, the booster pump does 
not run 

2)

 

When the tap has been turned off (around 
10seconds), the booster pump is still running 

 

Faulty high pressure switch 

1) 

Replace high pressure switch 
 

2) 

The water is still running but the booster pump 
does not run. 

3) 

The water has stopped running, but the booster 
pump is still running. 

 

Low pressure switch 

1) 

Replace the new low pressure switch 
 

1)

 

The water is running to drain continuously 
 

Auto shut-off valve 

1)

 

Replace the auto shut-off valve 

2)

 

The booster pump does not start and no water to 
service 

No water to service 

1)

 

Ensure power supply is on 

2)

 

Ensure water supply is on 

3)

 

Ensure there is no water leakage 
 

1)

 

Leakage on booster pump 
 

Water running inside unit 

1)

 

Call Monarch Water 

2)

 

Booster pump runs normally but no water to 
service 
 

No water to service 

1)

 

Replace all membranes 

1)

 

Bad tastes and odours in the water 
 

Cartridge capacity exhausted 

1)

 

Replace all inline cartridge’s 

1)

 

Total dissolved solids (TDS) in the water 
 

Membranes fouled 

1)

 

Replace all membranes 

1)

 

Booster pump runs intermittently when the 
system is not in use 

Stop, start water flow 

1)

 

Check all connections for leaks 

2)

 

Unplug power supply, turn off water supply and 
call Monarch Water 
 

 
 
 
 
 

Monarch Water Ltd, Halesworth Road, Bramfield, Suffolk. IP19 9HP 

Tel: 01986 784759.   Fax: 01986 784769.     

[email protected]

        

www.monarchwater.co.uk

 

Summary of Contents for ROF700

Page 1: ...High flow reverse osmosis water purifier with additional faucet Monarch ROF700 Installation Manual Effective June 2014...

Page 2: ......

Page 3: ......

Page 4: ...speedfit connection used chamfer edge of tubing to ensure internal o ring in speedfit is not damaged Mains Water Connection isolating valve Procedure 1 Remove the 2 screws holding the bracket togethe...

Page 5: ...ed Accompanying the unit will be a selection of speedfit connections suitable for and male threads for POU All of them terminate at 3 8 speedfit to suit the grey flexible tubing with the unit Simply m...

Page 6: ...over off The rear section can then be removed by undoing the 4no recessed and 1no surface mounted brass screw behind left hand membrane in the dark grey plastic main body Remove the membrane from its...

Page 7: ...this will give salty water to service E After 30 minutes turn off power Connect 3 8 grey tube currently over sink to appliance F Turn power back on and wait until pump turns off The pump turning off...

Page 8: ...nufacturer of your unit includes 50 years of manufacturing experience to give you a water purifier that is arguably the most reliable on the market today One of the aspects incorporated into the manuf...

Page 9: ...service 1 Ensure power supply is on 2 Ensure water supply is on 3 Ensure there is no water leakage 1 Leakage on booster pump Water running inside unit 1 Call Monarch Water 2 Booster pump runs normally...

Page 10: ...te work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date...

Reviews: