Monarch ROF700 Installation Manual Download Page 5

 
 

Drain/Waste Water Connection 

 

 

 
 
Prior to installing the drain connector, please inspect drain pipes for damage, frailty, or wear. 
 
Drain saddle valves are designed to be installed on standard 1.25 and 1.5” OD drain pipe.  
Install drain saddle valve above (and before) the trap and on the vertical or horizontal tailpiece. 
Never install a drain saddle valve close to the outlet of a waste disposal or plugging of the RO drain line will occur. 
 
Procedure: 
1. Position the threaded half of the drain saddle valve at the selected location and mark for the opening.  
Tip: Mark outline around top and bottom of drain saddle before removing for drilling as this helps reposition at No3 below. 
2. Drill 1/4” hole at the mark through 

this

 

side of the pipe only

3. Position both halves of the drain saddle on the drain pipe so threaded opening lines with the hole.  
4. Secure the drain saddle firmly using the nuts and bolts provided. 
5. Slide compression nut over ¼” black tubing. 
6. Push in insert then tighten nut on drain saddle thread to seal. 

Pure Water Connection on appliance

 

 

 

Storage Tank required? 
 

      

 

 
 
Accompanying the unit will be a selection of speedfit connections suitable for ½” and ¾” male threads for POU. All of them 
terminate at 3/8” speedfit to suit the grey flexible tubing with the unit. 
Simply ‘mix and match’ these fittings to get the desired connection you require. 
Additionally there will be enclosed speedfit connectors for the main Connection Point. 
There is also supplied a white 3/8” x 3/8” speed fit isolating valve that can be used to isolate the storage tank/appliance 
during general maintenance. 

On every speedfit connection used, chamfer edge of tubing to ensure internal ‘o’ ring in speedfit is not damaged. 

 
 
If stored water is required then Monarch offers a range of storage tanks for use with the ROF700. All units are designed for 
drinking water use so can be used on any mains water application. All tanks come complete with connection to 3/8” speedfit. 
Simply cut in the 3/8” speedfit tee (supplied) at the position marked on the FLOW DIAGRAM FOR ROF700 between the 
PERMEATE Connection Point and the appliance and run 3/8” grey tubing from this tee to the storage tank.  

 

Storage Tanks: 
24, 55 and 80 litre storage tanks are currently available. Additional sizes available on request. 
Please only allow 60% of the tanks rated capacity for actual water available. 
 
 

Summary of Contents for ROF700

Page 1: ...High flow reverse osmosis water purifier with additional faucet Monarch ROF700 Installation Manual Effective June 2014...

Page 2: ......

Page 3: ......

Page 4: ...speedfit connection used chamfer edge of tubing to ensure internal o ring in speedfit is not damaged Mains Water Connection isolating valve Procedure 1 Remove the 2 screws holding the bracket togethe...

Page 5: ...ed Accompanying the unit will be a selection of speedfit connections suitable for and male threads for POU All of them terminate at 3 8 speedfit to suit the grey flexible tubing with the unit Simply m...

Page 6: ...over off The rear section can then be removed by undoing the 4no recessed and 1no surface mounted brass screw behind left hand membrane in the dark grey plastic main body Remove the membrane from its...

Page 7: ...this will give salty water to service E After 30 minutes turn off power Connect 3 8 grey tube currently over sink to appliance F Turn power back on and wait until pump turns off The pump turning off...

Page 8: ...nufacturer of your unit includes 50 years of manufacturing experience to give you a water purifier that is arguably the most reliable on the market today One of the aspects incorporated into the manuf...

Page 9: ...service 1 Ensure power supply is on 2 Ensure water supply is on 3 Ensure there is no water leakage 1 Leakage on booster pump Water running inside unit 1 Call Monarch Water 2 Booster pump runs normally...

Page 10: ...te work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date...

Reviews: