background image

 
 
 

Cartridges and Membranes layout 

 

 

 
                          
 
 
 
                               (1). Sediment Cartridge 
 
 
                               (2). Carbon Cartridge 
 
 
                               (3). Membranes (one situated in rear of unit) 
 
 
                               (4). Carbon Cartridge 

 

Membrane replacement 

 

 

 

 

 

The ROF700 has 3no membranes. They are all inserted during unit manufacture prior to use and tested for leaks.  
Two are situated in the front section of the unit and one in the rear section.  
Remove the front section cover by gently squeezing side walls of front cover whilst pulling cover off. The rear section can 
then be removed by undoing the 4no recessed and 1no surface mounted brass screw (behind left hand membrane) in the 
dark grey plastic main body. 
 
Remove the membrane from its holding clip and release the compression connection in the cap and remove cap as pictured 
left. Remove membrane from its sealed bag and insert as per same picture. 
 
IMPORTANT: 
Ensure double ‘o’ ring seals on inserted end of membrane locate securely in female insert in base of membrane housing. 
 
 
Repeat the above until all membranes are inserted. 
Refit membrane cap, then reseal compression compressions. 
Refit all membrane housings in position. 

 

Summary of Contents for ROF700

Page 1: ...High flow reverse osmosis water purifier with additional faucet Monarch ROF700 Installation Manual Effective June 2014...

Page 2: ......

Page 3: ......

Page 4: ...speedfit connection used chamfer edge of tubing to ensure internal o ring in speedfit is not damaged Mains Water Connection isolating valve Procedure 1 Remove the 2 screws holding the bracket togethe...

Page 5: ...ed Accompanying the unit will be a selection of speedfit connections suitable for and male threads for POU All of them terminate at 3 8 speedfit to suit the grey flexible tubing with the unit Simply m...

Page 6: ...over off The rear section can then be removed by undoing the 4no recessed and 1no surface mounted brass screw behind left hand membrane in the dark grey plastic main body Remove the membrane from its...

Page 7: ...this will give salty water to service E After 30 minutes turn off power Connect 3 8 grey tube currently over sink to appliance F Turn power back on and wait until pump turns off The pump turning off...

Page 8: ...nufacturer of your unit includes 50 years of manufacturing experience to give you a water purifier that is arguably the most reliable on the market today One of the aspects incorporated into the manuf...

Page 9: ...service 1 Ensure power supply is on 2 Ensure water supply is on 3 Ensure there is no water leakage 1 Leakage on booster pump Water running inside unit 1 Call Monarch Water 2 Booster pump runs normally...

Page 10: ...te work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date...

Reviews: