Monacor PA-1960 Instruction Manual Download Page 8

8

English

coloured markings identifying the terminals in 
your plug, proceed as follows:
1 . The wire which is coloured green and yellow 

must be connected to the terminal in the plug 
which is marked with the letter E or by the 
earth symbol  , or coloured green or green 
and yellow .

2 .  The wire which is coloured blue must be con-

nected to the terminal which is marked with 
the letter N or coloured black .

3 .  The wire which is coloured brown must be 

connected to the terminal which is marked 
with the letter L or coloured red .

Warning – This appliance must be earthed.

If the unit is to be put out of operation 
definitively, take it to a local recycling 
plant for a disposal which is not harmful 
to the environment .

3  Applications

The amplifier PA-1960 with an RMS output power 
of 960 W is specially designed for applications 
in PA systems . A line level input is provided for 
background music and standard announcements; 
a second line level input is provided for emer-
gency announcements or other important an-
nouncements . By means of a separate switch or 
an external relay, it is possible to switch over to 
the second input .

The PA-1960 is also easily integrated into an 

existing PA system if more power is required for 
further speakers . For this purpose, it is equipped 
with a 100 V input .

4  Installation of Additional 

Modules

The amplifier can be extended by the following 
additional modules from MONACOR:
PA-6FD  fault detection module
PA-6FM  fault monitoring module

WARNING

Additional modules must always 
be installed by skilled personnel . 
Prior to opening the amplifier, dis-
connect the mains plug from the 
socket, otherwise you will risk an 
electric shock!

If an emergency power supply unit is connected, 
disconnect it from the terminals BATTERY (21) 
to ensure that the amplifier is out of operation .

4.1  Fault detection module PA-6FD

The fault detection module PA-6FD available as an 
accessory is specially designed for this amplifier . It 
will generate a 20 kHz sinusoidal test tone which 
is fed to the power amplifier . If the test tone is 
not applied to the SPEAKER OUTPUTS (9) due 
to a defect in the amplifier, the LEDs FAULT and 
PROTECT (5) will light up . Furthermore, the green 
LED (14) on the rear side of the amplifier will go 
out . Via a relay, a signal device can be activated 
in addition .

4.1.1 Installation and connection

SW 1

ON  OFF

CN601

Fault Detector

COM HOT

Line In

Sensitivity

OSC Level

PA-6FD

PA-6FD

min.

max.

Sense

a

b

d

c

e

1)  Unscrew the housing cover of the amplifier 

and remove the cover plate (19) . Disconnect 
the 4-pole cable that is fixed to the cover plate .

2)  Set the jumper SW 1 on the module to the 

position ON .

3)  Insert the module at the position of the cover 

plate from the outside and screw it on .

4)  Connect the 4-pole cable that was fixed to the 

cover plate to the jack CN 601 of the module . 
Make sure that the upper pin of the jack is not 
connected, see figure of the module .

5)  Connect the terminal strip SPEAKER OUTPUT 

(9) of the amplifier to the terminal strip “Line 
In” (b) of the module as follows:

COM  HOT

COM

1

SPEAKER

OUTPUTS

2 3

Line In

– (b)

(a) –

PA-1960

PA-6FD

6)  Set DIP switch No . 2 (13) on the rear side of 

the amplifier to the upper position OFF and 
DIP switch No . 3 to the lower position ON .

However, if the SLAVE INPUT (11) is used 

and a 20 kHz test tone from another amplifier 
is already applied here, set DIP switch No . 3 
to the upper position OFF, otherwise two test 
tones will be superposed!

7)  If the module detects a fault, the LEDs FAULT 

and PROTECT (5) will light up and the relay 
contacts 

COM  HOT

COM

1

SPEAKER

OUTPUTS

2 3

Line In

– (b)

(a) –

PA-1960

PA-6FD

 (a) will close . The contacts allow 

connection of a signal device for alarm trigger-
ing . The current rating of the relay contacts is 
1 A at ~ 120 V max . or 

  24 V  max .

 

 Note:

 The relay contacts will also close when the 

amplifier is switched off .

4.1.2 Calibration

An oscilloscope or a voltmeter is required which 
is able to measure alternating voltage up to 
20 kHz min .
1)  Switch on the amplifier and set the volume 

controls PGM (1) and LEVEL (16) to zero so 
that only the 20 kHz test tone is applied to 
the speaker outputs .

If the SLAVE INPUT (11) is used, no signal 

of an announcement or no music signal must 
be applied to this input while calibrating; only 
a 20 kHz test tone from another amplifier, if 
necessary . If a 20 kHz test tone is applied, skip 
the next step and proceed with step 3 .

2)  Measure the voltage of the 20 kHz test tone 

at the contacts COM and 3 of the SPEAKER 
OUTPUTS (9) . Use the trimmer potentiometer 
OSC Level (d) to set the level to 2 V (5 .6 V

pp

) .

3)  Turn up the trimmer potentiometer Sensitivity 

(e) until the LED Sense (c) lights up . From this 
position, turn the potentiometer to the scale 
mark after the next . The LED may flicker during 
operation; this is not a fault .

4)  After calibrating, set the controls PGM (1) and 

LEVEL (16) back to the desired volume .

4.2  Fault monitoring module PA-6FM

PA-6FM

PA-6FM  FAULT MONITOR MODULE

AC

DC

FAN

CN5

f

 

The fault monitoring module PA-6FM available 
as an accessory is specially designed for this am-
plifier . The three relay outputs (f) allow activation 
of signal devices in case of the following faults:
The relay contacts 

AC

 will switch over if no mains 

voltage is applied, if the internal mains fuse has 
blown, or if the amplifier has not been switched 
on with the POWER switch (6) .
The relay contacts 

DC

 will switch over if the internal 

fuses for the emergency power supply have blown 
or if no voltage from an emergency power supply 
unit is applied to the terminals BATTERY (21) .
The relay contacts 

FAN

 will switch over if the in-

ternal fan is defective or not connected .

Note:

 All relay contacts will also switch over when the 

amplifier is switched off .

1)  Unscrew the housing cover of the amplifier 

and remove the cover plate (18) . Disconnect 
the 6-pole cable fixed to the cover plate from 
the plate .

2)  Lead the 6-pole cable which was fixed to the 

cover plate outwards through the new open-
ing created and connect it to the jack CN 5 of 
the module .

3)  Insert the module PA-6FM at the position of 

the cover plate from the outside and screw 
it down .

4)  Connect the signal devices for alarm trigger-

ing to the switch-over relay contacts (f) . The 
marking on the module shows the contact po-
sition in case of defect and with the amplifier 
switched off . The current rating of the relay 
contacts is 1 A at ~ 120 V max . or 

 24 V max .

5  Setting Up the Amplifier

The amplifier is provided for installation into a 
rack for units with a width of 482 mm (19”), but 
it can also be used as a table top unit . In any case, 
make sure that air will circulate freely through 
all vents to provide a sufficient cooling of the 
power amplifier .

Summary of Contents for PA-1960

Page 1: ...R SPECIALISTS ELA Hochleistungsverst rker High Power PA Amplifier BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UG...

Page 2: ...FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS Deutsch Seite 4 English Page 7 Fran ais Page 10 Italiano Pagina 13 Nederlands Pagina 16 Espa ol P gina 19 Polski Strona 22 Dansk...

Page 3: ...ATTERY SPEAKER OUTPUTS 2 3 FACTORY SETTINGS A SPEAKER OUTPUT TABLE INSIDE 75 V 60 V 50 V 85V 70V 60V 100 V 85V 75V A B C SPEAKER OUTPUT SETTINGS 1 2 3 VOLTAGE IMPEDANCE 100 V 10 85V 7 2 75V 5 6 70 V 4...

Page 4: ...PRI CTL f r einen Vorrangschalter bei ge schlossenem Vorrangschalter schaltet der Verst rker vom Eingang PGM INPUT 12 auf den Eingang PRIORITY INPUT 17 um 16 Lautst rkeregler LEVEL f r das Signal am...

Page 5: ...der max 24V Hinweis Der Relaiskontakt schlie t auch wenn der Verst rker ausgeschaltet wird 4 1 2 Kalibrierung Es wird ein Oszilloskop oder ein Voltmeter be n tigt das Wechselspannungen bis mindestens...

Page 6: ...sschalten Der Verst rker l sst sich ber einen separaten Schalter ferngesteuert ein und ausschalten 1 Die Schraubanschl sse POWER REMOTE 22 ber eine zweipolige Leitung mit einem ein poligen Ein Ausscha...

Page 7: ...switch for remote controlled activation de activation Note For remote control the amplifier must not be switched on with the POWER switch 6 23 Mains cable for connection to a mains socket 230V 50Hz 2...

Page 8: ...tion ON However if the SLAVE INPUT 11 is used and a 20kHz test tone from another amplifier is already applied here set DIP switch No 3 to the upper position OFF otherwise two test tones will be superp...

Page 9: ...tions 6 5 Remote controlled activation deactivation The amplifier allows remote controlled activation deactivation via a separate switch 1 Connect the terminals POWER REMOTE 22 via a two pole cable to...

Page 10: ...20kHz lorsque le module PA 6FD est ins tall voir chapitre 4 1 1 point 6 14 LED de contr le brille lorsque l amplificateur fonctionne correctement 15 Bornes OUT pour la sortie 24V la tension est toujo...

Page 11: ...alibrage Un oscilloscope ou un voltm tre est n cessaire pour pouvoir mesurer les tensions alternatives jusqu 20kHz minimum 1 Allumez l amplificateur et tournez les r glages de volume PGM 1 et LEVEL 16...

Page 12: ...WER REMOTE 22 via un c ble 2 p les un interrupteur marche arr t 1 p le 2 Pour une marche arr t distance l amplifica teur ne doit pas tre allum avec l interrupteur principal POWER 6 6 6 Alimentation et...

Page 13: ...osizioni 15 e 16 sensibilit per pilotaggio massimo 0 775V 0dBu 18 Mascherina va tolta se si monta il modulo se gnalazione errori PA 6FM 19 Mascherina va tolta se si monta il modulo controllo errori PA...

Page 14: ...delle tensioni alternate fino a 20kHz min 1 Accendere l amplificatore e girare i regolatori del volume PGM 1 e LEVEL 16 sullo zero affinch solo il tono test di 20kHz sia presente alle uscite per gli...

Page 15: ...ore non deve essere stato ac ceso con l interruttore principale POWER 6 6 6 Alimentazione di corrente e d emergenza 1 Se l amplificatore deve continuare a funzionare anche dopo la caduta della rete oc...

Page 16: ...3 voor het in en uitschakelen van het testsignaal van 20kHz als de module PA 6FD is ingebouwd zie hfdst 4 1 1 bedieningsstap 6 14 Controle LED licht op als de versterker naar behoren werkt 15 Aanslui...

Page 17: ...tact bedraagt 1A bij max 120V of max 24V Opmerking Het relaiscontact sluit ook wanneer de versterker wordt uitgeschakeld 4 1 2 Kalibrering U hebt een oscilloscoop of een voltmeter nodig om wisselspann...

Page 18: ...n afzonderlijke schakelaar kunt u de verster ker afstandsbediend in en uitschakelen 1 Verbind de schroefaansluitingen POWER RE MOTE 22 via een tweepolige kabel met een eenpolige POWER schakelaar 2 Voo...

Page 19: ...st instalado Posici n superior OFF si el m dulo est instalado No 3 Activar desactivar el tono de test de 20kHz si el m dulo PA 6FD est insta lado ver apartado 4 1 1 paso 6 14 LED indicador se ilumina...

Page 20: ...sconecte el amplificador 4 1 2 Calibraci n Se necesita un osciloscopio o un volt metro con capacidad para medir voltajes alternos de hasta 20kHz m n 1 Conecte el amplificador y ajuste los controles de...

Page 21: ...los terminales POWER REMOTE 22 mediante un cable de dos polos a un interrup tor ON OFF de un polo 2 Para la activaci n desactivaci n por control remoto el amplificador no debe conectarse con el inter...

Page 22: ...wej cia PRIORITY INPUT 17 17 Symetryczne wej cie sygna u liniowego PRIO RITY INPUT dla wa nych komunikat w patrz te p 15 i 16 czu o 0 775V 0dBu 18 Pokrywa ochronna zdejmowana przed mon ta em modu u mo...

Page 23: ...macniacza 4 1 2 Kalibracja Do przeprowadzania procesu kalibracji konieczne jest zastosowanie oscyloskopu lub woltomierza z funkcj pomiaru napi sygna w o cz stotliwo ci powy ej 20kHz 1 W czy wzmacniacz...

Page 24: ...dalnym sterowaniu wzmac niacz nie mo e by w czony na prze czniku POWER 6 6 6 Zasilanie i zasilanie awaryjne 1 Aby zapewni ci g prac wzmacniacza w przypadku zaniku napi cia zasilania siecio wego do ter...

Page 25: ...v nd inte enheten och ta omedelbart kon takten ur eluttaget om n got av f ljande fel uppst r 1 Enheten eller elsladden har synliga skador 2 Enheten r skadad av fall e d 3 nheten har andra felfunktione...

Page 26: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 0799 99 03 08 2018...