IDT Ribbon Cable Hand Tool Module
Doc No: ATS-621002000 Release Date: 09-25-98
UNCONTROLLED COPY
Page 4 of 4
Revision: F
Revision Date: 08-13-08
Figure 8
CABLE IN ‘FEED THROUGH’
OR ‘DAISY CHAIN’ POSITION
CABLE IN ‘FEED TO’ POSITION
CABLE STOPS HERE
OPERATION
1.
Slide the IDT Ribbon Cable Module out to the
load/unload position.
2.
Load the proper connector making sure the
lower housing is facing up.
3.
Push the IDT Ribbon Cable Module into the
termination position. See Figure 7.
4.
Load the cable making sure it is locating in the
cable guides and sliding it into the connector
assembly until it contacts the cable stop, or
until it is at the correct length. See Figure 8.
5.
Terminate the connector onto the cable by
squeezing the tool handle until the ratchet
releases allowing the tool to open. See Figure
1. There is a full cycle ratchet mechanism. Should this tool jam the ratchet mechanism will prevent the
handle from being released before the termination is complete, and the cycle will not be completed. Use the
ratchet release shown in Figure 1 to reset the hand tool.
6.
Slide the IDT Ribbon Cable Module out and remove the assembly.
REPAIR POLICY
Molex does not repair the IDT Ribbon Cable Module. If the module, handle, or power adapter becomes damaged,
a new tool must be purchased. Hand tools are intended for prototyping or portable termination applications. They
are not intended for continuous duty production.
Americas Headquarters
Lisle, Illinois 60532 U.S.A.
1-800-78MOLEX
[email protected]
Far East North Headquarters
Yamato, Kanagawa, Japan
81-462-65-2324
[email protected]
Far East South Headquarters
Jurong, Singapore
65-6-268-6868
[email protected]
European Headquarters
Munich, Germany
49-89-413092-0
[email protected]
Corporate Headquarters
2222 Wellington Ct.
Lisle, IL 60532 U.S.A.
630-969-4550
Fax: 630-969-1352
Visit our Web site at http://www.molex.com
Figure 7
62100-2000
MODULE
SLIDE MODULE IN
LOAD CONNECTOR
62100-2000 MODULE
SLIDE MODULE OUT