background image

IDT Ribbon Cable Hand Tool Module 

Doc No: ATS-621002000  Release Date: 09-25-98 

UNCONTROLLED COPY

 

Page 3 of 4 

Revision: F 

Revision Date: 08-13-08 

 
3.

 

Slide the adjustable stop to the connector just tight enough to hold the 
connector in position without making it difficult to remove. 

4.

 

Retighten the M2.5 SHCS. 

5.

 

Molex recommends trying several connectors to be sure of a proper fit. 

 

Cable Stop Adjustment 

 
1.

 

For “Feed-To” harnesses, loosen the M3 BHCS and slide the cable 
stop to the up position.  Retighten the screw. 

2.

 

For “Feed-Through” or “Daisy-Chain” type harnesses, loosen the M3 
BHCS and slide the cable stop to the down position 

3.

 

Retighten the screw.  See Figure 5. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Termination Height Adjustment 

 
All connector should be terminated to a final height of 9.13mm ± .10. 
 
1.

 

To adjust the termination height, remove the two (2) screws that lock the notched wheels on the backside of 
the power adapter. 

2.

 

Turn the two (2) wheels, shown in Figure 6 an equal amount.  Clockwise to decrease the termination height, 
or counterclockwise to increase the height.  One (1) notch is .05mm (.002”).  See drawing SD-87568-003 for 
details. 

3.

 

When the correct height is achieved, replace the two (2) locking screws. 

LOCKING 

SCREW (2) 

Figure 6 

NOTCHED 

WHEEL (2) 

M3 BHCS 

CABLE STOP IN 

UP POSITION 

Figure 5 

CABLE STOP IN 

DOWN POSITION 