LW004-CT
16 www.mokosmart.com
function.
When the APP connect with the device success the phone system time will be sync to the device.
Device Time MAC Commands: LW004-CT supports the DeviceTime feature, which enables users to
periodically time their devices to avoid time offset.
3.8 Configuration Tool
The device can use MKLoRa app developed by Moko for quick OTA upgrades and parameter
settings. About the detail of MKLoRa, pls refer to
LW004-CT APP Guid
e
.
4 Uplink Payload
This section describes the payload messages supported by the LW004-CT.
There are five types of data reported through LoRa.
4.1 Device Information Payload
The LW004-CT will report the equipment information packet regularly, the default report interval
is 4 hours.
Byte Index
Type
Data
Type
Value
Description
Byte0
Payload Type
Uint
0x02
02 means Device Information
Payload.
01: Alarm data
Byte1
Battery Level
Uint
0x00-0x64
Convert to decimal, unit is %.
Byte 2
Alarm Enable
Setting
Uint
0x00
–
0x01
00 means disable; 01 means
enable.
Byte 3
-
8
The host MAC
Uint
0X000000000000
-
0XFFFFFFFFFFFF
The byte order is Big
-
Endian.
Example: B1 FA 1E 36 EF 03,
the real MAC address is B1 FA
1E 36 EF 03. The host refers to
the LW004
-
CT that reports the
data.
Byte 9
-
10
The hardware
version of
LW004
-
CT
Uint
0X0000
-
0XFFFF
Example: If it is 0x
2
1
0A
, the
hardware version is V
2
.
1
.
10
.
Byte 11
-
20
ADV Name of
LW004
-
CT
Uint
0X0000000000000
0000000
-
0XFFFFFFFFFFFFFF
FFFFFFFF
Convert to ASCII.