LW004-CT
22 www.mokosmart.com
Byte 35
RSSI of 2nd
Location Beacon
Int
0X00
-
0XFF
Converts directly to
decimal numbers, then
Minus 256. The unit is
dBm.
Byte 36
-
41
MAC address of
3rd Location
Beacon
Uint
0X000000000000
-
0XFFFFFFFFFFFF
The byte order is Big
-
Endian. Example: B1 FA
1E 36 EF 03, the real
MAC address is B1 FA 1E
36 EF 03.
Byte 42
RSSI of 3rd
Location Beacon
Int
0X00
-
0XFF
Converts directly to
decimal numbers, then
Minus 256. The unit is
dBm.
Byte 43
-
48
MAC address of
4th Location
Beacon
Uint
0X000000000000
-
0XFFFFFFFFFFFF
The byte order is Big
-
Endian. Example: B1 FA
1E 36 EF 03, the real
MAC address is B1 FA 1E
36 EF 03.
Byte 49
RSSI of 4
th
Location Beacon
Int
0X00
-
0XFF
Converts directly to
decimal numbers, then
Minus 256. The unit is
dBm.
4.5 3-Axis Payload
➢
Users can choose to report content according to application scenarios.
➢
The smaller the number of bytes per payload, the shorter the transmission time and the lower
the power consumption.
➢
The optional reported contents are as follows:
①
Timestamp
②
The host MAC
Byte Index
Type
Data Type
Value
Description
Byte0
Payload Type
Uint
0x03
03 means SOS Alarm
Payload
01: Alarm data
Byte 1 – 7
Timestamp
Uint
0X00000000000000
-OxFFFFFFFFFFFFFF
Convert to decimal. Byte
1
-
2 represents the year;
Byte 3 represents the
month; Byte 4
represents the date;
Byte 5 represents the
hour; Byte 6 represents
minute; Byte 7
represents second;