AB 4071-6 / AB 4071-12
Ø 2,5mm
1
2
Installation Instructions
Installation on Mounting Bracket
Installation of Actuators
For flexible wires, open
the clamp with a screw-
driver and plug the cable
in.
A maximum of 13 Actuators may be connect-
ed to the Basis Wireless. 4 (2) actuators may
be connected per channel. However, several heating
zones can be allocated to a Wireless Thermostat.
A maximum of 4 actua-
tors per heating zone
can be connected to the
6 room base, and 2 actua-
tors per heating zone can
be connected to the 12
room base.
Push the actuator cables
into the clamp.
Following the installation of the Actuators onto the
heating circuit valves (see actuator installation instruc-
tions) the Actuator must be connected to the Basis
Wireless as follows.
Plug/clamp connections
The following wire types are suitable for the plug/
clamp connections:
solid wire: 0.5 - 1.5 mm²
flexible wire: 1.0 - 1.5 mm²
For a proper connection, 10 mm of the line ends
should be stripped.
The Actuator wire’s factory-mounted end sleeves pro-
vide a proper connection without stripping.
3
3
<3 mm