Disassembly
!
Note:
Larger valves may require that the actuator
remain installed
in order to
rotate the ball position prior to the removal of valve from piping.
Larger valve / actuator combinations with limited clearance may
require removal of the valve and the actuator from piping as
separate
components
.
Smaller valve / actuator combinations with adequate clearance may
typically be removed from piping as
one assembly
.
CAUTION!
Verify that the ball is in the
fully closed
position
prior to actuator removal and valve disassembly .
REMOVE OPERATOR
If operator is present, remove per instructions
provided by manufacturer .
REMOVE MOUNTING FLANGE ADAPTOR
If mounting flange adaptor is present, it must be
removed .
Note:
Mark any matching components with a marker, tape, etc., prior to
disassembly, for ease of reassembly.
1
2
Before beginning any work, identify the valve model
by checking the number on the side of the valve body .
To locate the model number, see page
34
,
Locate
Valve Information
.
Mark any matching components with a marker, tape,
etc ., prior to disassembly, for ease of reassembly .
!
CAUTION!
If you disassemble, rework and re-assemble this
ball valve,
YOU WILL VOID YOUR WARRANTY
.
REMOVE VALVE
Remove valve from piping .
Note:
Support or lift as required.
Let valve rest on body end with bore vertical .
3