be replaced.
3.
Fault
: Charging started normally, but did not
complete, and stopped. Green+Red lights
are lit.
Probable cause 1
: The battery has a fault that does
not permit it to be charged, e.g. a short circuit.
Action
: Replace the battery (with lead-acid type).
Probable cause 2
: Parallel load. If there is an
equipment using current from the battery while
charging, the charger may not be able to charge
the battery within the safety time limit set for
safety reasons.
Action
: Disconnect the parallel load and repeat
charging, or purchase a more powerful charger
that can handle the extra load.
Probable cause 3
: Battery is too large and could
not be charged within the set safety time limit.
Action
: Repeat charging.
4.
Fault
: The flashlight does not come on when the
charger´s power cable is plugged into the mains
socket.
Probable cause
: No power in mains socket. Or the
flashlight LED is broken. (You can still use the
charger but it will be without flashlight function).
MAINTENANCE
The charger is entirely maintenance-free. It has no user-
serviceable parts. Opening the charger will void the warranty.
The case may be cleaned using a soft, damp cloth. The
charger must be disconnected from the mains when being
cleaned.
ACCESSORIES
The charger comes with clamp cables and a set of ring
terminal cables, which can be used for fixed installations. To
change cables, press the unlock flange on the connector and
pull it out. Connect the desired new cable. Push it all the way.
The flange should lock it.