Network and Power Connection, Additional Cables
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
2.5.8 Camera Startup Sequence
As soon as the power supply has been established, LEDs 1 and 2 will show the progress
of the startup sequence.
•
Booting:
Immediately after connecting the power supply, the red LED lights up, blinks
for two seconds, then stays on permanently red. A camera self-test is carried out at
this point, and the entire system is started. In case of an error, the camera will start
using the backup operating system.
•
Waiting for key pressed:
Both LEDs light up for four seconds. If you press the
R or
L key of the camera
during this time, the camera will execute the corresponding
function (see
Section 3.2.5, «Starting the Camera with the Factory IP Address» and
Section 3.2.6, «Starting the Camera with an Automatic IP Address (DHCP)»).
•
Ready:
Once the camera software has been started, the green LED is on permanently
and the red LED blinks. The camera can now be accessed via the network (browser,
MxControlCenter, MxEasy, MOBOTIX App, etc.).
Note
During the startup sequence of the camera, the LEDs will always light up, even if they
have been deactivated in
Admin Menu > LED Setup
.
R
L
2
1
LED defaults:
1
Power (on), Error (flashes)
2
Recording (flashes)
1. Start
2. Key
3. Ready