84
/128
M25 Camera Manual: Installation
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
2.7.9 Camera Startup Sequence
As soon as the camera’s power supply has been established, the two LEDs will show the
progress of the startup sequence (see
Section 5.4.3, «LED Signals and LED Configuration»,
in the MOBOTIX
Camera Software Manual Part 2).
•
Booting:
Immediately after connecting the power supply, the red LED lights up, blinks
for two seconds, then stays on permanently red. The camera runs a self-test at this
point, and starts the entire system after that. In case of an error, the camera will
start using the backup system.
•
Waiting for key pressed:
Both LEDs light up for four seconds. If you press the
R or
L key of the camera
during this time, the camera will execute the corresponding
Section 3.2.4, «Starting the Camera with Factory (Network) Settings»
and
Section 3.2.5, «Starting the Camera with an Automatic IP Address (DHCP)»). To
press a key, use a
paper clip
for example, but
never use sharp or pointed objects!
•
Ready:
Once the camera software is running, the green LED is on permanently and
the red LED blinks. You can now reach the camera via the network (using a browser,
MxManagementCenter, MOBOTIX App, etc.).
Note
During the startup sequence of the camera, the LEDs will always light up, even if they
have been deactivated in
Admin Menu > LED Setup
.
1
2
R
L
LED default settings
1
Power (on),
Error (flashes)
2
Recording (flashes)
1. Booting
2. Key?
3. Ready