Mobius M9 SORTER User Manual Download Page 27

CLEANING & 

MAINTENANCE

Summary of Contents for M9 SORTER

Page 1: ...2 0 2 1 E T E R O S T E C H N O L O G I E S I N C A L L R I G H T S R E S E R V E D M O B I U S T R I M M E R C O M USER GUIDE MOBIUS M9 AUTOFEED CONVEYOR...

Page 2: ...CONTENTS...

Page 3: ...on supplied by component manufacturers are to be considered the information package associated with this device Every operator must read and understand the User Guide The manual should be located with...

Page 4: ...SAFETY...

Page 5: ...icipal provincial state county territorial and federal codes regulations and standards have been met in each working location Do not lend or rent your machine without providing the User Guide A first...

Page 6: ...azards that are exposed when guards are removed It may also be used to alert against unsafe practices Indicates a potentially hazardous situation that if not avoided may result in minor or moderate in...

Page 7: ...other jewelry which may get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair 6 POWER DOWN AND DISCONNECT EQUIPMENT before washing servicing an...

Page 8: ...INITIAL SETUP...

Page 9: ...9 GET TO KNOW YOUR CONVEYORS 2 0 2 1 E T E R O S T E C H N O L O G I E S I N C A L L R I G H T S R E S E R V E D M O B I U S T R I M M E R C O M...

Page 10: ...PS 1 x CONTROL PANEL WITH TOOL STORAGE 4 x 2 HEX BOLTS 4 x NUTS 4 x WASHERS FOR HEX BOLTS 2 x 1 BUTTON HEAD SCREWS 6 x 3 8 BUTTON HEAD SCREWS 4 x 5 8 BUTTON HEAD SCREWS 2 x SIDE PANELS 2 x HOPPER HAND...

Page 11: ...H BASE by using 2 x 2 HEX BOLTS 2 x WASHERS and 2 x NUTS The head of the bolts should sit within The head of the bolts should sit within The head of the bolts should sit within the hexagonal cutouts...

Page 12: ...4 Install the TALL H BASE UPRIGHT to the H BASE using the same hardware in the last step...

Page 13: ...h the conveyor body Then slide 2 x THROUGH STOPS on to the protruding ends of the THROUGH SUPPORT BARS Ensure the lip on the THROUGH STOPS is flush with the sheet metal With the THROUGH STOPS installe...

Page 14: ...M O B I U S T R I M M E R C O M 6 Install the BELT onto the conveyor body by simply sliding it on to each end Ensure the groove along the underside of the BELT is aligned in the grooves on the roller...

Page 15: ...7 Install a SIDE PANEL on each side of the conveyor by aligning the circular cutouts with the THROUGH STOPS and THROUGH BARS Simply slide each panel down onto the pucks to install it on the conveyor...

Page 16: ...O L O G I E S I N C A L L R I G H T S R E S E R V E D M O B I U S T R I M M E R C O M 8 Join the side panels to each other by installing the HOPPER HANDLES Align a handle with the screw hole cutouts...

Page 17: ...UE THE BELT TENSIONING STUB PERMANENT DAMAGE MAY RESULT The TENSIONING TOOL can be stored in the keyhole cutout on the CONTROL BOX 11 Once initial assembly is complete inspect the conveyors to confirm...

Page 18: ...OPERATIONS...

Page 19: ...Slide the conveyor belt on to the metal body from the side of the machine 2 Ensure the groove on the underside of the belt is positioned in the slots of the rollers at each end You ll feel the belt c...

Page 20: ...counterclockwise to reduce belt speed RIGHT DIRECTION CONTROL flipping the direction switch will change the travel direction of the belt CONTROL PANEL OVERVIEW MACHINE START UP SEQUENCE 1 Plug the pow...

Page 21: ...ack up and running in no time TO REPLACE BEARINGS ON THE TENSIONING SIDE OF YOUR AUTOFEED CONVEYOR BEARING REPLACEMENT 1 Start by removing the side panels 2 Use the conveyor tensioning tool to remove...

Page 22: ...Using a 5 32 hex key remove the 4 screws securing the plate to the two side arms 7 Using a 9 64 hex key remove the flathead screw from the round bar that spans across the tensioning assembly on the si...

Page 23: ...ve the bearing and install your new bearing in the bore Then reinstall the plate you removed in the previous step NOTE if the problematic bearing is in the arm on the right pictured below there are tw...

Page 24: ...E MOTOR SIDE OF YOUR AUTOFEED CONVEYOR 1 Remove the side panels and belt as per steps 1 and 2 of the previous section 2 Remove the 4 bolts securing the motor to the conveyor using a 6mm hex key then s...

Page 25: ...key remove the 4 bolts securing the motor assembly to the conveyor body Removie the motor and set these aside in a safe place 4 Grab the roller and slide the entire motor assembly out of the conveyor...

Page 26: ...einstall the plate you removed in the previous step 8 Slide the motor assembly back into the conveyor body and secure it with the 4 screws that were removed earlier Note that there are 3 sets of holes...

Page 27: ...CLEANING MAINTENANCE...

Page 28: ...e OFF position and disconnect the power cord 2 Remove the hopper 3 Remove the belt from the body of the conveyor 4 Spray down or soak the belt in diluted degreaser for 5 10 minutes If necessary use a...

Page 29: ...Power Requirements Length Construction Belt Material Belt Length Motor Tools Height Yes 1 11 5 110 V 1 5 A Matte White Polyurethane 304 Stainless Steel and Delrin 77 1 10 HP Mobius tensioning tool inc...

Page 30: ...1 866 874 6264 INFO MOBIUSTRIMMER COM MOBIUSTRIMMER COM Eteros Technologies West 202 17665 66A Ave Surrey BC V3S 2A7 Eteros Technologies East 26 Industrial Ave Carleton Place ON K7C 3T2...

Reviews: