Technical Installation Guide (4G) v1.9
www.mobileye.com
13
Mobileye 8 Connect
5.4 Ferrite
5.4.1 Ferrite for Power Sources -Model 1 (ITM000786)
5.4.2 Instructions for power sources (CAB000371)
Please follow the instructions bellow for the two ferrites
installation:
1.
Place both Mobileye
BAT+
wire and
Ignition
wire (CAB000371)
together inside the first Ferrite.
2.
L
ocate the Ferrite 5cm from the Mobileye CAB000371 label
3.
Wrap the
BAT+
and
Ignition
wires through the Ferrite 2 times
and
around the outside
of the Ferrite 1 times, as shown in the figures
4.
Place the Mobileye GND wire in the second Ferrite
(
locate the Ferrite filters 5cm from the Mobileye
CAB000371 label).
5.
Wrap the GND wire through the Ferrite 2 times and around the outside of the Ferrite
1 times, as shown in the figures
The Ferrite size and shape may vary different between different Ferrite models.
Ferrite installation on power lines is mandatory in CE marking countries.