Power cord
Pressure-
adjust knob
Inflation nozzles
(connect here the
Inflation tubes)
Power switch
Foldable hook hangers
(on the top back side
of the pump)
Mobilex A/S
Grønlandsvej 5
DK-8660 Skanderborg
www.mobilex.dk
The content is:
✔
1 Pump
✔
1 Mattress pad with inflation tubes
✔
1 User manual
P05 compressor (pump)
Assembly description
Looking on the picture above the device should be assembled in a quite instinctive way.
We recommend you to follow below steps:
•
In the first place take all elements out of the box and check with the list from above if nothing is
missing.
•
If you’d discover at that stage that some parts are missing or damaged, do not continue assembly
•
process. Contact your supplier of the product right away.
•
Lay the mattress pad on a foam base or other regular bed mattress. Do not put it directly on the
bed frame. Please refer to the Specifications section for details.
•
The inflation tubes should be towards the foot end so that they can be connected to the inflation
nozzles on the pump.
•
Cover it with a cotton sheet to avoid direct skin contact and reduce friction.
•
Hang the pump over the frame or board at the foot end of the bed using the foldable hook
hangers. Make sure the pump is secured.
•
Connect the ends of the inflation tubes to the mattress pad nozzles and to the pump’s inflating
nozzles. Make sure the tubes are properly attached and that they are fitted tight on the nozzles.
•
Make sure the inflation tubes are not kinked or tucked under the pad.
•
Before inserting the plug into the outlet, make sure the voltage is compatible.
•
Plug the power cord into an electrical outlet with AC power. Replace or repair if damaged.
•
Make sure this product is well grounded.
•
Make sure to disconnect the pump by unplugging the power cord when it is not in use.
Function description
•
Turn on the power by pressing the power switch at the right side of the pump. The indicator of the
power switch will come on. The pump starts to pump air into the mattress pad.
•
For time-saving in the first inflation, turn the pressure knob to the full Firm/Hard position. It
requires approximately 10 minutes for a bubble pad to be fully inflated.
•
When mattress pad is fully inflated turn the pressure-adjust knob to set a comfortable pressure
level from soft to firm according to patient’s weight and comfort.
•
It is recommended that the pressure-adjust knob being turned to Firm when the bubble pad is
firstly inflated. Users can then easily adjust the pressure level of the bubble pad to a desired
firmness by themselves or according to the suggestion from a health care professional.
•
If the pressure is consistently low, check for any leakage occurring in inflation tubes. Contact your
local dealer for replacement of any damaged tubes.
•
The deflating/inflating cycle runs automatically, when pump is turned on.
Cleaning & maintenance
It is important to follow these procedures for cleaning and decontamination of the pump and bubble pad
before using the system on patients. The cleaning is required at least once a week to maintain personal
hygiene.