background image

 

 

 

 

 

 

USER MANUAL 

 

 

 

Mobeye

®

 CombiGuard  

CM4600 

 

SW version 1.n

 

Summary of Contents for CombiGuard CM4600

Page 1: ...USER MANUAL Mobeye CombiGuard CM4600 SW version 1 n...

Page 2: ......

Page 3: ...4 Basics of the Mobeye Internet Portal 15 4 5 How to activate the CombiGuard 17 4 6 System reset 18 5 Possible settings 19 5 1 Alarm phone numbers 19 5 2 Test message 19 5 3 Input type 20 5 4 Alarm d...

Page 4: ...3 7 2 How to activate the CombiGuard 28 7 3 System reset 28 7 4 SMS reports when using own SIM card 29 7 5 Technical messages 30 8 Status feedback 31...

Page 5: ...ended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the de...

Page 6: ...lti provider and can be used internationally it may choose from several providers per country In case of a network problem it will switch to another provider or fall back to 2G In addition the Mobeye...

Page 7: ...eye CombiGuard sends an alarm message to the Mobeye Internet Portal to be forwarded to the alarm contacts As soon as the voltage recovers a recovery message is sent In case the second input is activat...

Page 8: ...alarm SMS text message and calls the phone numbers programmed in by the user The SMS message contains the text Temperature too high or Temperature too low followed by the measured temperature As soon...

Page 9: ...be switched via SMS command When an external power supply is used and a power failure occurs the Mobeye CombiGuard sends a power failure SMS text message and calls the numbers When the power is resto...

Page 10: ...t the batteries 6 Connect an external power supply optionally 7 Connect a sensor to the additional input optionally 8 Programming when using the Mobeye SIM Portal a Sign up in the Mobeye Internet Port...

Page 11: ...wn SIM card An own SIM card has a micro format is suitable for the 2G network and can make calls and send text messages The PIN code is 0000 or the SIM card is PIN code free A PIN code can be changed...

Page 12: ...tically after an alarm or after receiving the SMS text message CODE O1ON and CODE O1OFF e g 1111 O1ON It is possible to make this switch only during a pulse time after which it automatically switches...

Page 13: ...the connector press on the green pins to connect the wires Mobeye adapter 10027 position V to black lead with white stripe left Ground to black lead 2nd from left 3 8 CONNECT A SENSOR TO INPUT 1 OPTIO...

Page 14: ...f in case the unit has not been configured yet In a battery operated unit a time out occurs after 3 minutes after which the communication module switches off in order to save the batteries In this low...

Page 15: ...tten on the plastic SIM card below the barcode You can take the entire number or only the last 8 digits If the SIM card and batteries are already installed a pop up will appear where you assign a name...

Page 16: ...irst blink red green while connecting to the network 4 4 BASICS OF THE MOBEYE INTERNET PORTAL Dashboard With multiple devices the dashboard shows all devices with the alarm messages in the last 24 hou...

Page 17: ...essages you link the contact persons who receive alarm and service messages via push notification call text message and or e mail Service messages can be warnings about missed test messages and low ba...

Page 18: ...h on arm the Mobeye CombiGuard Press the button at the backside for 1 second The green LED blinks once every 3 seconds battery powered or stays on continuously in case of an external power supply If p...

Page 19: ...pply 2 Press the outside button while reinserting the batteries Keep it pressed for about another 5 seconds 3 Release the button immediately after the LED starts to flash 4 If relevant connect the ext...

Page 20: ...is disarmed The Mobeye Internet Portal expects the test message and checks the timely receipt The monitoring of the test messages follows the management by exception rule only if the message was not...

Page 21: ...seconds As default the input delay time is set to 1 second for input 1 and input 2 For the water sensor it is 30 seconds The delay for the temperature alarm is adjustable in minutes with the factory...

Page 22: ...set to C 5 10 THRESHOLD VALUE FOR THE BATTERY VOLTAGE To monitor the battery voltage the lower limit needs to be programmed It is advised to set a value where the battery voltage is too low but the b...

Page 23: ...mmand CODE O1OFF e g 1111 O1OFF By default the pulse time is set to 5 seconds 5 15 AUTOMATIC ARMING DISARMING The Mobeye CombiGuard only works if the unit is armed which is done via the on off button...

Page 24: ...he factory mode is set to OFF the communication module will always have a network connection When set to ON the behaviour is the same as for a battery powered device the communication module is turned...

Page 25: ...ands and settings In a battery operated unit a time out occurs if no correct command is received for 3 minutes after which the communication module switches off in order to save the batteries In this...

Page 26: ...number The TEL1 telephone will receive a confirmation text message with the security code SMS command 1st telephone number CODE TEL1 example 1111 TEL1 07212345678 similar for TEL2 TEL5 To program int...

Page 27: ...EIN1 NO NC AN NO Input type input 2 TYPEIN2 NO NC AN AN Delay on input 1 DELAY1 0 999 sec 1 Delay on input 2 DELAY2 0 999 sec 1 Delay on water input DELAY3 0 999 sec 30 Inactive time input 1 INACTIVEI...

Page 28: ...oo high Alarm text high temperature TEXT2 20 characters Temperature too low Text alarm restore TEXT3 20 characters Temperature OK Alarm text NO NC input 1 TEXT4 20 characters Alarm 1 Alarm text NO NC...

Page 29: ...once every 3 seconds battery powered or stays on continuously in case of an external power supply If powered externally with network connection switching can be done via SMS commands SMS command to s...

Page 30: ...ombiGuard can be requested by sending an SMS text message with the content without code STATUS REQUEST The status includes the armed disarmed status status of the inputs power and batteries The status...

Page 31: ...replaced External power supply OK batteries OK The external power is restored or the adapter is plugged in a socket batteries do not need to be replaced delayed message If delayed message is added to...

Page 32: ...he network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another lo...

Page 33: ...32...

Page 34: ...and by max ca 500 mA Dimensions 94 x 94 x 28 mm Ambient temperature 10 C until 50 C Temperature sensor head 35 C tot 70 C This product is designed and manufactured in the Netherlands For more informat...

Page 35: ...34...

Page 36: ......

Reviews: