28
7.2
HOW TO ACTIVATE THE COMBIGUARD
After the previous steps the Mobeye CombiGuard is ready for use. It is
armed automatically.
In order to switch off (disarm) the CombiGuard:
- Press the button at the backside for 1 second.
The green LED switches off to indicate the
disarmed status.
In the disarmed status the Mobeye
CombiGuard will not send alarm notifications.
The unit remains active and is able to switch
on time-controlled and to send 'low battery
voltage' messages.
In order to switch on (arm) the Mobeye CombiGuard:
- Press the button at the backside for 1 second. The green LED blinks once
every 3 seconds (battery-powered) or stays on continuously (in case of an
external power supply).
If powered externally (with network connection), switching can be done via
SMS commands:
SMS command to switch on:
CODE ARM
(e.g. 1111 ARM)
SMS command to switch off:
CODE DISARM
(e.g. 1111 DISARM)
7.3
SYSTEM RESET
To reset the Mobeye CombiGuard to its factory settings:
1.
Remove the batteries (and external power supply).
2.
Press the outside button while reinserting the batteries. Keep it pressed
for (about) another 5 seconds.
3.
Release the button immediately after the LED starts to flash.
4.
If relevant, connect the external power supply.
After a successful reset, the status LED will blink green to indicate that the
module is not configured. The security code is back to factory settings as
well.