32
7.4 SYSTEM RESET
To reset the Mobeye CML2255 to its factory settings:
1. Remove the batteries (and external power supply).
2. Press the outside button while reinserting the batteries. Keep it pressed for
(about) another 5 seconds.
3. Release the button immediately after the LED starts to flash.
4. If relevant, connect the external power supply.
After a successful reset, the status LED on the keypad will blink green to indicate
that the module is not configured. The security code is back to factory settings as
well.
7.5 SMS REPORTS WHEN USING OWN SIM CARD
Several lists and status reports can be retrieved by sending an SMS text message to
the Mobeye CML2255, from any telephone number. Before sending the request,
make sure the unit is in the program mode (please refer to 6.1).
Upon sending the command, the Mobeye CML2255 returns an SMS text message to
the originator of the request. The commands are case insensitive.
ACTUAL TEMPERATURE
The actual temperature values as measured by the Mobeye CML2255 can be
requested by sending an SMS text message with the content (without code):
?
STATUS REQUEST
The status can be requested by sending following SMS text message. The status
includes the armed/disarmed status, status of the inputs, power and batteries.
SMS command status request:
STATUS?
example:
1111 STATUS?