31
7.2 SWITCHING ON/OFF
After the previous steps the Mobeye CML2255 is ready for use. It is armed (switched
on) automatically. It can be switched on and off by the user-defined time schemes or
the button on top. By default this button i
s ‘locked’, to prevent that the unit can be
switched off by mistake. This can be changed by choosing t
he value “OFF” for the
setting “BUTTONLOCK” (see 5.17). After unlocking the button, the system can be
switched on and off pressing it for one second.
When the unit is switched off, the green LED is off. When the unit is on, the green
LED blinks once every 3 seconds (battery-powered)
or stays ‘on’ continuously (in
case of an external power supply).
In the disarmed status the Mobeye CML2255 will not send alarm notifications. The
functions automatic arming and
‘low battery’ notifications are still active.
If powered externally (GSM is open), switching can be done via SMS commands:
SMS command to switch on:
CODE ARM
SMS command to switch off:
CODE DISARM
example:
1111 ARM
The status can be requested via SMS command CODE STATUS?.
7.3 CONFIRMATION OF THE ALARM MESSAGE
When the system is triggered it will send alarm notifications. First an SMS text
message is sent to all programmed alarm numbers, followed by a phone call. When
you pick up the phone, you will hear beeps. It is possible to acknowledge the phone
call by answering the phone and pressing any key. The other alarm numbers will not
be called afterwards. This works for most telephones.
By switching off the SMS function the system will only call. This prevents the other
numbers being notified by SMS.