© MOBATIME
29 / 32
800697.09
11
Technical data
11.1 Standard design of the clock
Note for the IP40 modification (excluding PoE variant): The power connector can be
considered as an IP40 only if it is connected to the clock. Otherwise it is considered as an
IP30 accessory.
11.2 Voltage range and electric current consumption of the lines
Technical data
ECO-DC
57.4
57.6
57x.6 100.4 100.6 100x.6
Display
height of the digits
57
57/38
57
100
400/57
100
number of digits
4
4+2
6
4
4+2
6
Time display format
HH : MM
✓
✓
HH : MM:
SS
✓
✓
HH : MMSS
✓
✓
Date display format
DD. MM
✓
✓
DD.MM
YY
✓
✓
DD.MM.YY
✓
✓
Automatic or manual display brightness
✓
Viewing distance
25 m
40 m
Autonomous operation
Internal quartz base
Synchronization
MBL
MOBALine time code, mains powered
MBLDCF
MOBALine or active DCF 77 time code, mains
powered
IRIG
IRIG-B, mains powered
NTP, WiFi
NTP protocol, mains powered
PoE
NTP protocol, powered over PoE
(compatible IEEE 802.3af)
Power supply
100 - 240 VAC / 50 - 60 Hz
24 VDC (option, not for PoE version)
Power consumption
AC/DC version
single sided design
7 VA
8 VA
8 VA
7 VA
8 VA 10 VA
double sided design
11 VA 16 VA 16 VA 11 VA 16 VA 18 VA
Power consumption
PoE version
single sided design
7 VA
8 VA
8 VA
7 VA
8 VA 10 VA
double sided design
11 VA 15 VA 15 VA 11 VA 15 VA 15 VA
Quartz accurancy
at 20°C
accuracy without
synchronization
±0,3 sec/day
RTC backup
supercapacitor for 12 hours
Operating temperature
-
5 to + 55°C
Protection degree
IP 30 (IP40 on request)
Weight [kg]
single sided design
0,75
1,15
1,25
1,8
1,9
2
double sided design
2
2,8
3
4,1
4,3
4,5
Dimensions
(WxHxD) [mm]
single sided design
341 x 122 x 49
580 x 180 x 60
double sided design
341 x 122 x 99
580 x 180 x 120
Type of slave line
Voltage range
Electric current consumption
MOBALine
5
– 30 VAC
6
– 34 uA
Active DCF 77
+- 12
– 30 V
3 - 7 mA
IRIG B
20 mVpp
– 2 Vpp
20 uA
– 2 mA