INSTALLATION
Note – Microwave sensors may not be suitable for all installations, for example enclosed
spaces, as they are able to detect movement through non-metallic surfaces like
plasterboard and thin doors.
SUSPENSION MOUNTING
• To suspend the fitting, screw the mounting hoop into the top of the luminaire and secure
with the screw provided
SURFACE MOUNTING
• When installing with the AXBRAC surface mount bracket (not included): using the bracket
as a template, mark the location for, and drill the fixing holes ensuring not to infringe with
any gas/water pipes or electrical cables
• Secure the bracket to the surface using suitable fixings which must be adequate to
support the weight of the luminaire
• Remove the bolts on either side of the bracket, align the bracket to the luminaire screw
holes, and refasten the bolts
WIRING
• Provide power to the required point of installation
• Connect the luminaire to the mains supply ensuring the correct polarity is observed: Live
(brown), Earth (green/yellow), Neutral (blue)
•
The luminaire can be connected to a 0-10V dimmer (see Fig. 2). Please note that both Signal
DIP switches must be in the ON position for this function to operate. This luminaire can be
controlled via DALI (AXDMOD is required, control gear and software not supplied) (see Fig. 1)