Handling Warnings

The SG524  has two handles on the front panel to help 
unpacking and handling operations: never use only the 
handles to lift the equipment but support the weight with 
an appropriate base on bottom!
The handles do not withstand the off-center weight of the 
equipment ( kg 14= 31 lbs).

General Description

The SG524 is a solid state generator able to provide up to 450 
W at the frequency of 2450 MHZ (2.45 GHz) and is powered 
through a wide input AC/DC power supply with input range 
from 120 to 230 Vac.
The output power can be adjusted continuously, from 1% 
up to 100%,  using   an external analog  signal from 0.1 to 

10Vdc, or by remote control through fieldbus interface or by 

manual commands (depending from equipment version: see 
next table).
The genetor offers the capability to adjust the output fre-
quency over a total range of +/- 50 MHz with respect the 
nominal frequency of 2450 MHz.

The SG524 is built in a self-ventilated  19” wide rack, 2 HE 
high, with a front panel including a graphic display: the rear 
panel carries connectors for an easy set-up.

As of today the SG 524 is offered in two versions:
- the “Display” version with front panel manual commands 
and PLC interface to control by I/O: it carries also one USB 
standard port, which allows to drive/read data from the unit 
with a simple software (like our “Front Panel” software distri-
buted freely). 
- the “Bus” version (vers. 1) which implements an industrial 

bus interface (like CANopen or Modbus/TCP or Profibus), 

allowing connection of multiple devices on the same bus.

SG 524 Versions Overview

MODEL ABBREV.

BUS

DISPLAY

Version no.

1

2

External Control (PLC)

possible

possible

LED Panel Indicators

n.a.

n.a.

Local Commands (Manual)

possible

Graphic Interface

Network Control

n.a.

USB Control (possible, not a default set-
ting)

n.a.

Frequency control (ISM band range)

Front and Rear Panel Layout

(In the following descriptions the numbers in brackets [ n ] refer to 

numbers in the annexed drawing).

The front panel of version 2 “Display” contains:
- Main Switch 0-1 [1]
- the User interface: Graphic Display, three push-buttons [2] 
and a rotaing knob [3]

  ESC 

allows moving from one page to another, 

  TAB 

(the  button  with  the  arrow)  to  scroll  down  the  selection,               

  

ENTER

 to confirm the selection.

  

Knob 

allows to modify a value when this is enabled.

- a standard USB port [4]
For a detailed description see the chapter “Manual Com-
mands” on next pages.
The manual commands are active only when the related 
option is enabled: if it is not selected, then the unit can run 
only with External commands.

2

4

3

8

1

Front 

View

Rear 

View

9

7

5

6

Summary of Contents for SG 524

Page 1: ...SOLID STATE MICROWAVE GENERATOR 450 W 2450 MHZ TECHNICAL NOTE issue April 2017 SG 524...

Page 2: ...Cover Rear...

Page 3: ...i membri relative alla compatibilit elettromagnetica Conformity to the Directives is assured through the application of the following standards La conformit alle Direttve assicurata tramite l applicaz...

Page 4: ...tion alone must be included into a larger process equipment and it s for stationary use Nevertheless we invite the User to respect the following Directive rules this WEEE is not a municipal waste and...

Page 5: ...Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement With reference to Basic Standard EN55011 this equipment i...

Page 6: ...lay version with front panel manual commands and PLC interface to control by I O it carries also one USB standard port which allows to drive read data from the unit with a simple software like our Fro...

Page 7: ...f 9 450 Adjustable range 2 100 Max value differs at frequency band limit Output linearity Wrf 5 Forward power Displayed value vs monitor signal Output stability 1 For input fluctuations within 10 Outp...

Page 8: ...your external contactor Once switched OFF wait at least two seconds before setting it ON again The OFF state between two consecutive ON state must last two seconds minimum The following description is...

Page 9: ...LINE BREAKER 0 1 in pos 1 the unit goes in POWER ON The line switch can be freely switched off at any time POWER SET it s an analog input value and has the meaning of desired percent of the full outp...

Page 10: ...u generate a directory named program_name containing the micro code to be loaded an executable program named SendApplicationProgram bat and the loader sRecLoad exe Once unpacked the zip program enter...

Page 11: ...generator was running before entering into autotune mode The user may adjust the various parameters via three buttons and a rotating knob on the front panel as follows ESC button used to return back t...

Page 12: ...n case of heavy standing wave the generator may be overloaded with the sum of both forward and reverse power and parts of the circuit on the final power combiner as well as the coaxial socket may be d...

Page 13: ...84810 1 Preferred size other length on request max 2 m Coax Cable 7 8 with 7 16 Plugs l 1m 441384811 1 Other length on request max 4 m 3 Transition 7 16 to WR340 MWR26 COAX7 16L Aluminum construction...

Page 14: ...gnals in the range 0 10Vdc pin 2 and pin 3 ground on pin 15 and 16 respectively Forward and Reverse Power Monitor CONN 2 LOCATION Forward Power Wrf 1 Vmon 45 W Pin no 2 return on pin 15 Reverse Power...

Page 15: ...for the protocol implemented Each SG 524 generator must be associated to an address the two digital rotating switches must be used the left switch sets the tens the right sets the units Depending fro...

Page 16: ...1 1 Plug for CONN 1 included on Plug Set MOCPC03 3 1 Connector Sub D type 25 pin female CONN 2 4 1 AC DC power supply 120 240V 32 V out PLRSP200032 5 1 Anybus CC interface Profibus Modbus PLAB62xxx S...

Page 17: ...alarm persist contact the service 0100 Internal Safety Relay Malfunction The internal safety relay could have been damaged i e by a shortcircuit on the contact Try to restart the unit If the alarm per...

Page 18: ...ET524 contains plugs for Conn 1 and 5 only Coax Plug right angle 7 16 M F p n MWCOAX7 16L Coax cable length 1 m 1 2 p n 441384810 1M0 Same as above 2 m p n 441384810 2M0 Cable set for input line and s...

Reviews: