Checking operation
38
Installation instructions
7 Checking operation
DANGER
Risk of personal injury and physical damage from
unsuccessful operational check
•
Do not put the unit into service.
•
Contact customer service.
Requirement
Power connection made
Water connection made
Wastewater connection made
Unit cleaned
7.1 Checking the air recirculation hood
Requirements
Cooking zone door closed
1. Switch on the unit.
The fan for the air recirculation hood runs continuously.
2. Open the cooking zone door.
The fan for the air recirculation hood runs faster.
The air recirculation hood is connected correctly.
3. Switch off the unit.
4. Fill out the Commissioning report.
7.2 Checking the controls
1. Switch on the unit and start any cooking program (see Operating
instructions).
Set the cooking zone temperature to a higher temperature than
the current cooking zone temperature.
The unit heats up.
Once the set temperature is reached, heating switches off.
The temperature no longer increases.
The controls are functioning.
2. Switch off the unit.
3. Fill out the Commissioning report.
4127002--0AIBE-C