Connecting the unit
34
Installation instructions
6.5.1 Connecting the tap water connection line
a
b
c
f
e
d
Image: Water connection
a Softened tap water
d Tap water connection
b Connection line
e Backflow preventer
c Soft water connection
f Tap water
Requirement
Water pressure complies with the specified range (see "Equipment
and connection data")
Backflow preventer installed
The connection lines are pressure-tight and suitable for tap water
1. Connect the connection lines to the tap water valves using seals.
2. Flush the connection lines thoroughly.
3. Insert dirt filters into the water connections on the unit.
4. Connect the tap water connection line to the unit.
5. Connect the soft water connection line to the unit.
6. Open the tap water valves and check the threaded connectors for
leaks.
7. Fill out the Commissioning report.
4127002--0AIBE-C