BX-4
34
MISTING SYSTEM OPERATION, MAINTENANCE & TROUBLESHOOTING
REPLACEMENT OF NOzzLES:
Step A:
Remove tube cover (1) by loosening 2 screws
on both side of blade guard with a phillips screw driver.
Step B:
Remove blade.
Step C
: Remove 2 retaining rings which hold nozzles in
place from the inner side of blade guard.
Step D:
Loosen nozzles by rotating counter-clockwise.
Step E
: Install new nozzles. Push fittings thru holes in
the blade guard & secure fittings by reinstalling retaining
rings from the inner side.
Step F:
Re-install tube cover (1). Secure tube cover with
phillip screws.
Disconnect unit from power supply.
CAUTION
1
Blade
Guard