26
HD-101r
SeTUp
Prior to beginning work, a pre-start inspection of the saw should be performed.
1. To prevent the possibility electrical shock, the HD-101R MUST be
de-energized when connecting the Water Pump.
2. To prevent the possibility of electrical shock, use only MK Diamond qualified
replacement parts
noTe: To prevent pump damage, the Water Pump must be disconnected if cutting with a Dry Blade.
(A)
Ensure the ON/OFF Switch is in
the OFF position
(B)
Verify the Movable Cutting
Table moves freely
(C)
Inspect the Diamond Blade for
damage – verify the blade is
correct for the material being cut
(D)
Inspect the Pump Assembly for
damage – ensure the cord is
free of cracks or cuts
(E)
Inspect the HD-101R for
damage
warninG
pre-STarT inSpeCTion
ConneCTinG THe waTer pUmp
(A)
Connect the Cooling Trans-
fer Tube to the inlet connec-
tion of the Blade Guard
(B)
Connect the Water Pump power
cord to the connection found on
the back of the motor