CHAPTER 6
ELECTRICAL SYSTEM
31
(forward most) indicating that the panel is receiving electric current.
ACTIVATE AC PANEL 1: When the green LED light appears on AC 1 Panel, turn ON double
Generator Selector switch for AC 1 ONLY. There is a delay until Volts (about 115) register in the
digital display over AC-1.
ACTIVATE AC PANEL 2: Select “CHARGE” on the Xantrex Panel and when the light comes on
Green, the double-Generator Selector switch for AC 2 can be turned ON.
See that AC volts are now
reading on the digital meter
over AC Panel 2.
TURN BREAKERS ON for the
items you wish to operate.
Note: if the generator starts,
but no AC voltage is seen at
the panel, check first that the
selector switches (sliding
interlocks) at the top of the AC
panel are ON. If so and still no
voltage reading, there is a
possibility the generator was
overloaded and the AC breaker
(on the generator itself) has
tripped due to a momentary
overload. Open the generator
cover and reset (pull up) the
AC Output Circuit Breaker.
STOP: First, remove any
electrical load from the
generator Allow the engine to
run for a 3-5 minute cool-down
period. Depress STOP
momentarily on the lower part
of the rocker switch.
Break-In Period
Change
engine oil and filter at 50 hours
and again at 100 hours. Oil
consumption is greater until
piston rings are seated.
Maintain at least a 75% load on
the generator for the first 100
hours, varying the load to help
seat the rings.