CHAPTER 6
ELECTRICAL SYSTEM
33
6.8
BONDING
The bonding system of your boat connects all underwater metallic fittings to the sacrificial zinc
and the boat’s negative bus bar. In order for the zinc to protect an underwater part, the
connection must be clean and secure. The green wires that make up this system are not normally
current carrying.
6.9
ELECTRICAL SAFETY
Please read and understand the important safety precautions included in the included ISO CE
Mark approved Owner’s Manual” concerning electrical safety.
6.10
BREAKER & FUSE LOCATIONS & SPECIFICATIONS
6.11
RAYMARINE FUSE LIST (Includes Options)
Chart Plotter
7 Amps
Autopilot X-Can
10 Amps
SeaTalk ng
3 Amps
SeaTalk
3 Amps
Network Switch
1 Amp
RD424D Digital Radar
15 Amps (10A breaker)
RS125 GPS
1 Amp
DSM 300 Fishfinder
8 Amps
Ray55 VHF radio
10 Amps
SR100 Sirius Receiver
2 Amps
SR6 Sirius Receiver / Network Switch
2 Amps
AIS 500 Transceiver
5 Amps
6.12
IN-LINE and ANL FUSE LIST/LOCATION
Item / Fuse Label
Size
Type
Location
1
Bilge Pump 1
5 amp
AGC
In the Bilge Pump Switch at the Dash
2
Bilge Pump 2
5 amp
AGC
In the Bilge Pump Switch at the Dash
3
Bilge Pump 3
5 amp
AGC
In the Bilge Pump Switch at the Dash
4
Bilge Pump 1
7.5 amp
ATC
Fuse Block next to House Battery 1 (Stbd
Settee Hatch)
5
Bilge Pump 2
7.5 amp
ATC
Fuse Block next to House Battery 1 (Stbd
Settee Hatch)
6
Bilge Pump 3
7.5 amp
ATC
Fuse Block next to House Battery 1 (Stbd
Settee Hatch)
7
Stereo Memory
15 amp
ATC
Fuse Block next to House Battery 1 (Stbd
Settee Hatch)
8
DVD Memory
15 amp
ATC
Fuse Block next to House Battery 1 (Stbd
Settee Hatch)