7
Down and up button change jump speed
6
FF00
Colorful Running
(
01
—
99
)
Down and up button change speed
7
BEB1
Colorful sound control
__1
8
ID00
DMX512 ID
,(
00
—
51
)
When the ID=0 the ID off
When press Enter key,Down and UP key can modify DMX 512 ID value.When
ID started,each time of start this light will display ID value in 5 secnods
9
FROM
Slave Mode
Maintenance:
To prolong the life of the projector, some maintenance work has to be done to ensure the LED optical system in
good condition. If the projector does not function, check the fuses on the power socket of the projector, they should
only be replaced by fuses of the same specification. Should these be damaged, call a qualified technician before
replacement. The projector has thermal protection device that will switch off the projector in case of overheating.
Should either of these operate, check that the fans are not blocked, and if they are dirty, clean them before
switching on the projector again. Check that the fans are operational, if not, call a qualified technician.
☆
Any maintenance work should only be carried out by qualified technicians.
Keeping The Product Clean:
To ensure the reliability of the projector, it should be kept clean. It is recommended that the fans should be cleaned
every 15 days. LED lens should also be regularly cleaned to maintain an optimum light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or particularly dirty
surroundings can cause greater accumulation of dirt on the unit's optics. A soft cloth and typical glass cleaning
products should be used for cleaning. It is recommended to clean the external optics at least once every 15 days.
☆
Do not use any organic solvent, e.g. alcohol, to clean housing of the apparatus.
Trouble Shooting:
Problem
Answer
The LED moving head light doesn’t switch on.
Check the fuse the power socket
Although shines, but the LED moving head lamp
doesn’t accept the instruction of the controller.
Check the digital start address and also check the
connection situation of the communication control
line
LED moving head lamp only can work
intermittently.
Inspect the power supply and voltage is whether
normal.
Do not receive the DMX512 signal.
Whether the signal lines do contact well or broken.
The light beam appears gloomily.
Check that the heat dissipation system is running
normally or Inspect the optics part is whether clean.
☆
Other maintain work should by the specialist which has the experience to carry on.