MFP250 / 400 / 800
Initial Start Up
76609594EN-MFP-NH-V2.0.docx 29/40
4.1.8.3
Initiator „Pincers locked“(Locking Cylinder)
Function:
Pincers locked
Item no.: 770.60989
Voltage range +V
s
:
12 - 27 V AC/DC
Max. load current:
100 mA
Schematic:
The initiator “Pincers locked” should always be set so that the LED illuminates as soon
as the weld pincers are in basic position.
This signal is evaluated during an automated sequence.
4.1.8.4
Version with Final Position Initiator
Start is only possible when the signal ‘locking mechanism active’ is available (signal 1).
If the signal is not available error message B2 ‘not ready’ is displayed.
4.1.8.5
Version with two Final Position Initiators
Start is only possible when the signal ‘locking mechanism active’ is available (signal 1).
After release of the locking cylinder the signal ‘Initiator locking cylinder open’ must be
available to enable the moving of the weld head.
For installation work deactivate the system!
Risk of injury!
The
head starts moving
if start remains closed and initiator open is assigned (e.g. by
manual adjustment)!