MFP250 / 400 / 800
Description Motor Head Control
76609594EN-MFP-NH-V2.0.docx 17/40
3.3.10
X112, X113: Default Assignment
The signals of the locking cylinder correspond in the AWS3 system to those of the
stroke cylinder.
Reference (R): device related = (D); process related = (P)
Symbol
Function
R
I/O
1 axis
operation
2 axis
operation
MFP Inputs
I_START_ON_1
Start axis 1
P
I17
X112.4
X112.4
I_START_ON_2
Start axis 2
P
I23
X112.10
I_FORSTROKE_ON_1
Go to waiting position axis 1
P
I18
X112.5
X112.5
I_FORSTROKE_ON _2
Go to waiting position axis 2
P
I24
X112.11
I_INT_CYL_LOCK_1
Locking/stroke cylinder
axis 1 back/bottom
P
I21
X112.8
X112.8
I_INT_CYL_LOCK_2
Locking/stroke cylinder
axis 2 back/bottom
P
I26
X112.13
I_INT_CYL_UNLK_1
Locking/stroke cylinder
axis 1 ahead/top
P
I22
X112.9
I_INT_CYL_UNLK_1
Locking/stroke cylinder
axis 2 ahead/top
P
I27
X112.14
I_EOC_1
Stepping contact axis 1
P
I_EOC_2
Stepping contact axis 2
P
I_REL_CURR_1
Release current axis 1
P
I_REL_CURR_2
Release current axis 2
P
I_REF_ELEC_1
Start reference run axis 1
P
I19
X112.6
X112.6
I_REF_ELEC_2
Start reference run axis 2
P
I25
X112.12
I_CRTL_ON_1
Activating controller axis 1
D
I_CRTL_ON_2
Activating controller axis 2
D
I_CRTL_OFF_1
Switching-off controller axis 1
D
I_CRTL_OFF_2
Switching-off controller axis 1
D
I_OP_MODE
Toggle between single Step
and automatic (ON =
Automatic mode)
D
I_RESET_FAULT
Acknowledge fault
D
I20
X112:7
X112:7
I_RELEASE_EXT
Release of external control
P
I_LOCKED_EXT
Interlocking of external control
D
I_PROG_BIT0
Program selection Bit 0
P
I_PROG_BIT1
Program selection Bit 1
P
I_PROG_BIT2
Program selection Bit 2
P
I_PROG_BIT3
Program selection Bit 3
P
I_PROG_BIT4
Program selection Bit 4
P
I_PROG_BIT5
Program selection Bit 5
P
I_PROG_BIT6
Program selection Bit 6
P
I_PROG_BIT7
Program selection Bit 7
P