84
-
'16 • SCM-T-199
Flaring
Finishing work and fixing
Connection wiring, Earth wiring
Outer tape
Refrigerant piping
Drain hose
Wood screw
Clamp
Cover the exterior portion with outer tape and
shape the piping so it will match the contours
of the route that the piping to take.
Also fix the wiring and pipings to the wall with
clamps.
RKY012A011A
Open/close and detachment/attachment of the air inlet panel
○
To open, pull the panel at both ends of lower part
and release latches, then pull up the panel until
you feel resistance.
(The panel stops at approx. 60
˚ open position)
○
To close, hold the panel at both ends of lower
part to lower downward and push it slightly until
the latch works.
○
To remove, pull up the panel to the position
shown in right illustration and pull it toward you.
○
To install, insert the panel arm into the slot on the
front panel from the position shown in right
illustration, hold the panel at both ends of lower
part, lower it downward slowly, then push it
slightly until the latch works.
How to remove and fit the front panel
○
Removing
Remove the air inlet panel.
Remove the 5 set screws.
Remove the 4 latches in the upper section.
Move the lower part of the panel forward and
push upwards to remove.
1
2
3
4
○
Fitting
Do remove the air filter.
Cover the body with the front panel.
Fit the 4 latches in the upper section.
Tighten the 5 set screws.
Fit the air filter.
Fit the air inlet panel.
1
2
3
4
5
6
Open the air inlet panel.
Remove the service panel.
Remove the wiring clamp.
Connect the connecting wire securely to the terminal block.
1)
Connect the connection wire securely to the terminal
block. If the wire is not affixed completely, contact will be
poor, and it is dangerous as the terminal block may heat
up and catch fire.
2)
Take care not to confuse the terminal numbers for indoor
and outdoor connections.
Fix the connecting wire by wiring clamp.
Attach the service panel.
Close the air inlet panel.
1
2
3
4
5
6
7
ELECTRICAL WIRING WORK
CAUTION
In case of faulty wiring connection, the indoor unit stops, and then
the run lamp turns on and the timer lamp blinks.
Use cables for interconnection wiring to avoid loosening of the wires.
CENELEC code for cables Required field cables.
H05RNR4G1.5 (example) or 245IEC57
H Harmonized cable type
05 300/500 volts
R Natural-and/or synth, rubber wire insulation
N Polychloroprene rubber conductors insulation
R Stranded core
4or5 Number of conductors
G One conductor of the cable is the earth conductor
(yellow/green)
1.5 Section of copper wire (mm
2
)
Preparation of indoor unit
Mounting of connecting wires
• Forced cooling operation
Turn on a power source again after a while after turn off a power source.
Then press continually the ON/OFF button 5 seconds or more.
○
Install the removed flared nuts to the pipes to be connected,
then flared the pipes.
○
Remove the flared nuts. (on both liquid and gas sides)
Keep the openings of the pipes covered with tapes etc. to prevent dust, sand, et
c. from entering them.
CONNECTION OF REFRIGERANT PIPINGS
Preparation
(Do not turn)
Press
Remove
A
Dimension A
Liquid side
ø6.35 :
0
9.1 (mm)
Gas side
ø9.52 : 13.2 (mm)
Gas side
ø12.7 : 16.6 (mm)
CAUTION
Do not apply refrigerating machine
oil to the flared surface.
Indoor
Copper pipe diameter
Use a flare tool designed for R410A or a conventional flare tool.
Please note that measurement B (protrusion from the flaring block) will vary dep
ending on the
type of a flare tool in use.
If a conventional flare tool is used, please use a copper pipe gauge or a simila
r instrument to
check protrusion so that you can keep measurement B to a correct value.
Clutch type flare tool for
R410A
Conventional (R22) flare tool
ø6.35
ø9.52
ø12.7
0.0 - 0.5
0.0 - 0.5
0.0 - 0.5
1.0 - 1.5
1.0 - 1.5
1.0 - 1.5
1.5 - 2.0
1.5 - 2.0
2.0 - 2.5
Measurement B (mm)
Clutch type
Wing nut type
CAUTION
Do not apply excess torque to the flared nuts.
Otherwise, the flared nuts may check depending.
○
Arrange the drain hose in a downward angle.
○
Avoid the following drain piping.
○
Pour water to the drain pan located under the heat exchanger, and ensure that t
he water is discharged outdoor.
○
When the extended drain hose is indoor, securely insulate it with a heat insula
tor available in the market.
CAUTION
Wall
Gutter
Pipe accommodating section
Since this air-conditioner has been designed to collect dew drops on the rear
surface to the drain pan, do not attach the power cord above the gutter.
Drainage
Go through all installation steps and check if the drainage is all right.
Otherwise water leak may occur.
Higher than specified
The drain hose tip is in water.
Wavy
The drain hose tip is in the gutter.
The gap to the ground is 5 cm or less.
Odor from the gutter
2
1
Installation Steps
Pass the pipe through
the hole in the wall,
and hook the upper
part of the indoor unit
to the installation board.
Gently push the lower
part to secure the unit.
• How to remove the indoor unit from the installation board
Fixing of indoor unit
Push up at the marked portion of the indoor unit base lower latch, and slightly
pull it toward
you. (both right and left hand sides) (The indoor unit base lower latch can be r
emoved from
the installation board)
Push up the indoor unit upward. So the indoor unit will be removed from the inst
allation board.
1
2
CONCERNING TERMINAL CONNECTION FOR AN INTERFACE
Remove the front panel and lid of control.
Remove the control.
There is a terminal (respectively marked with CNS) for the indoor control board.
In connecting an interface, connect to the respective terminal securely with the
connection harness
supplied with an optional
“Interface connection kit SC-BIKN-
E
” and fasten the connection harness
onto the indoor control box with the clamp supplied with the kit.
For more details, please refer to the user
’s manual of your
“Interface connection kit SC-BIKN-
E
”.
1
2
3
○
Connect the pipes on both liquid and gas sides.
○
Tighten the nuts to the following torque.
Liquid side (
ø6.35) : 14.0 - 18.0 N
·m (1.4 - 1.8 kgf
·m)
Gas side (
ø9.52) : 34.0 - 42.0 N
·m (3.4 - 4.2 kgf
·m)
Gas side
(
ø12.7) : 49.0 - 61.0 N
·m (4.9 - 6.1 kgf
·m)
Connection
Insulation of the connection portion
Indoor
Liquid side Gas side
(Do not turn)
• Cover the indoor unit s flare-connected joints, after they are checked for a ga
s leak, with an indoor unit
heat insulating material and then wrap them with a tape with an attached insulat
ion pad placed over
the heat insulating material
’s slit area.
Cover the coupling with insulator and then cover it with tapes.
Vinyl tape
Use an attached insulation pad for heat insulation.
Position it so that the slit area faces upward.
• Flaring work
Measurement B
block
Copper pipe
○
Uncover the wireless remote control, and mount the batteries [R03 (AAA, Micro),
×
2 pieces] in the body regularly.
(Fit the poles with the indication marks,
+
&
-
without fail)
○
Conventionally, operate the wireless remote control by holding
in your hand.
○
Avoid installing it on a clay wall etc.
Cover
CAUTION
Wood screws
ø3.5 X 16
Wireless remote control
Battery
INSTALLATION OF WIRELESS REMOTE CONTROL
Mounting method of battery
Fixing to pillar or wall
Do not use new and
old batteries together.
2
6
5
Disconnect
TIME SETUP
ACL
When two air-conditioners are installed in the same room, use this setting when
the two air-conditioners are not operated with one wireless remote control. Set
the
wireless remote control and indoor unit.
INSTALLING TWO AIR-CONDITIONERS IN THE SAME ROOM
Setting the wireless remote control
Pull out the cover and take out batteries.
Disconnect the
switching line next
to the battery with
wire cutters.
Insert batteries. Close the cover.
1
2
3
Setting an indoor unit
1
2
3
Turn off the power source, and turn it on after 1 minute.
Point the wireless remote control that was set according
to the procedure described on the left side at the indoor
unit and send a signal by pressing the ACL switch on
the wireless remote control.
Since the signal is sent in about 6 seconds after the ACL switch
is pressed, point the wireless remote control at the indoor unit for
some time.
Check that the reception buzzer sound "Pip" is emitted from the
indoor unit.
At completion of the setting, the indoor unit emits a buzzer sound
"pip". (If no reception tone is emitted, start the setting from the
beginning again.)
INSTALLATION TEST CHECK POINTS
After installation
The power
source
voltage is correct as the rating.
No gas leaks from the joints of the service valve.
Power cables and crossover wires are securely fixed to the terminal board.
The screw of the service panel is tightened securely.
Test run
Air-conditioning operation is normal.
No abnormal noise.
Water drains smoothly.
Protective functions are not working.
The wireless remote control is normal.
Operation of the unit has been explained to the customer. (Three-minutes resta
rt preventive timer)
When the air-conditioner is restarted or when changing the operation, the unit w
ill not start operating for
approximately 3 minutes. This is to protect the unit and it is not a malfunction
.
Service valve is fully open.
The pipe joints for indoor and outdoor pipes have been insulated.
Check the following points again after completion of the installation, and befor
e turning on the power. Conduct a test run again and ensure that the unit operat
es properly.
At the same time, explain to the customer how to use the unit and how to take ca
re of the unit following the user
’s manual.
Reception
Pip
Installing the air-cleaning filters
Air-cleaning filter
1. Open the air inlet panel and remove the air filters.
2. Install the air-cleaning filter in the filter holders, and then install the
filter holders in the air-conditioner.
• Each air-cleaning filter can be installed in the left or right filter holder.
3. Install the air filters and close the inlet panel.
Connect charge hose to check joint of outdoor unit.
Liquid side : Close the liquid valve with hexagon wrench key.
Gas side : Fully open the service valve (Gas side).
Carry out cooling operation. (If indoor temperature is low, operate
forced cooling operation.)
After low pressure gauge become 0.01MPa, stop cooling operation
and close the service valve (Gas side).
1
2
3
<How to pump down>
○
In order to protect the environment, be sure to pump down (recovery of refriger
ant).
○
Pump down is the method of recovering refrigerant from the indoor unit to the
outdoor unit when the pipes are removed from the unit.
HOW TO RELOCATE OR DISPOSE OF THE UNIT
The marked portion of the indoorunit
base lower latch.
Indoor unitI
Latch
(2 locations)
Installation
borad
Installa
tion borad
Wall
Indoor unit base lower latch
Set screws
latch
Terminal block
Service panel
Clamp
The screw of the service panel is tightened securely.
Filter holder
Unit ON/OFF button
•
Earth wire shall be Yellow/Green (Y/G) in color and longer than other AC wires f
or safety reason.
90°±
0.5