(8) Determining the operating mode
The cooling and heating operating modes are the wireless remote control mode that have been previously determined.
If a mode differing from these is selected after this, the selected mode will appear in the display of the wireless remote control,
but only the fan will operate.
A unit
B unit
COOL
COOL
FAN
HEAT
HEAT
FAN
Cooling
switch
ON
Heating
switch
ON
Heating
switch
ON
Cooling
switch
ON
Heating
switch
ON
Operation Operation
Operation Operation
Operation
Example of operating pattern
First operation
Second operation
Notes
Selected mode
Cooling
Heating
Example
1
2
Remote control display
COOL
HEAT
Operation
COOL
HEAT
Selected mode
Heating
Cooling
Remote control display
HEAT
COOL
• Different mode is
only fan operation.
Operation
FAN
(1)
FAN
Note (1) If the display shows heating and the operation is fan, Hot keep will operate.
Note (1)
indicates currect operation.
-
164
-
'16 • SCM-T-199
(b) Swing
Flap moves in upward and downward directions continuously.
S
In HEAT operation
S
In COOL, DRY operation
Approx. 35°
Approx. 65°
Approx.
20°
Approx. 59°
(c) Memory flap
When you press the AIR FLOW (UP/DOWN) button once while the flap is operating, it stops swinging at an angle. Since this
angle is memorized in the microcomputer, the flap will automatically be set at this angle when the next operation is started.
(d) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Sleep timer operation
Pr
essing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(c) OFF timer operation
T
h
e Off timer can be set at a specific time (in 10-minute units) within a 24-hour period.
(7) Timer operation
(a) Comfortable timer setting (ON timer)
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto
mode operation is selected, the comfortable timer starts and determines the starting time of next operation based on the initial
value of 15 minutes and the relationship between the room temperature at the setting time (temperature of room temperature
sensor) and the setting temperature.