 8. Transportation Precautions 

 

 
When transporting lithium batteries, make sure to treat them based on the 
transport regulations.  
 

8.1 Target Models of Regulations 

The batteries for the Web server module are classified as follows: 

 

Product name 

Model 

Product supply status 

Classification for 

transportation 

Q series battery 

Q6BAT 

Lithium battery 

Non-dangerous goods 

 

8.2 Transport Guidelines 

Comply with IATA Dangerous Goods Regulations, IMDG code and the local 
transport regulations when transporting products after unpacking or repacking, 
while Mitsubishi ships products with packages to comply with the transport 
regulations. 
Please consult your carrier for further details. 

 

CompactFlash is a registered trademark of SanDisk Corporation. 
All other company names and product names used in this manual are 
trademarks or registered trademarks of their respective companies. 

 

Summary of Contents for QJ71WS96 Series

Page 1: ...asing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL QJ71WS96 U HW JE MODEL CODE...

Page 2: ...ystem safety instructions In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury I...

Page 3: ...m of module insert the module fixing tab into the fixing hole in the base unit until it stops Then securely mount the module with the fixing hole as a supporting point Incorrect loading of the module...

Page 4: ...tor from the module Failure to do so may cause malfunctions or damage to the module or cable z Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris co...

Page 5: ...mpliance with the EMC and Low Voltage Directives Chapter 1 Chapter 2 Section 3 1 Section 5 1 Section 5 2 Section 8 1 Sep 2008 IB NA 0800231 E Correction SAFETY PRECAUTIONS Compliance with the EMC and...

Page 6: ...cautions 3 3 2 Installation Environment 3 4 Part Names 4 5 External Wiring 6 5 1 Connecting to the 10BASE T 100BASE TX 6 5 2 Connecting to the RS 232 7 6 Setting from GX Developer 8 7 External Dimensi...

Page 7: ...rporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual...

Page 8: ...s how to install the QJ71WS96 Web server module hereinafter referred to as Web server module and how to wire them with other devices Packing list Model name Product name Quantity QJ71WS96 Web server m...

Page 9: ...Parity check None Transmission control Flow control RS CS control is available Recommended cable 7 0 127 P HRV SV outside diameter 8 5mm or longer Oki Electric Cable Company Limited Specify the numbe...

Page 10: ...the following ranges Screw position Tightening torque range Remarks Module fixing screw usually not required M3 screw 1 0 36 to 0 48 N m RS 232 cable connector screw M2 6 0 20 to 0 39 N m Screw hole d...

Page 11: ...4 4 Part Names When LED cover is closed 1 1 2 3 9 When LED cover is opened 5 6 7 8 4 9...

Page 12: ...actFlash card mounting slot 7 Battery Battery for file protection 8 Battery connector pin Connector pin for battery lead The battery lead is not connected to the connector at shipment to prevent batte...

Page 13: ...100BASE TX connection a communication error may occur due to the effect of high frequency noise generated from the device other than programmable controller depending on the installation environment T...

Page 14: ...end 8 CS CTS Clear To Send 1 2 3 4 5 6 7 8 9 9 CI RI Ring Indicator 2 RS 232 interface connector The Web server module uses the following RS 232 interface connector y DDK Ltd 9 pin D sub Female screw...

Page 15: ...ogging monitor setting Switch 3 lower byte Response monitoring time setting Switch 4 to 5 For system use Do not set 1 Mode setting Switch 1 Select the operation mode for Web server module Setting numb...

Page 16: ...number 21 System name QJ71WS96 Does not execute network diagnoses Ping Automatic connection to network at start up Default operation setting IP filter setting 0 Operates according to the IP filter se...

Page 17: ...e timeout error will occur if the CPU of the accessed device does not respond to the request after the set time has passed Setting range 15 to 255 second default value 15 seconds Response monitoring t...

Page 18: ...The bending radius near the connectors reference value R1 should be four times as long as the cable s outside diameter or more when connecting the twisted pair cable 2 The bending radius near the conn...

Page 19: ...m battery Non dangerous goods 8 2 Transport Guidelines Comply with IATA Dangerous Goods Regulations IMDG code and the local transport regulations when transporting products after unpacking or repackin...

Page 20: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Reviews: