62
6
6
13
OPTIONAL PARTS
2-2 Feature of program timer
(1) Daily timer function
Daily timer can be set in 0 minutes units for up to 2 hours.
Each unit can be set for unit ON, unit OFF, or setback operation.
(2) Setback operation (PAC-SC2PTA)
Set back operation is useful for reducing running costs
e.g. At a hotel with a 2-hour system
8:00~2:00 Cooling operation with set temperature at 26°C
2:00~8:00 Setback operation with 2 degrees of setback
As shown in the chart on the right, the set temperature rises 2 degrees
automatically during the setback operation. When the setback operation
ends, normal operation will begin.
() Weekly timer function
Daily timer function can apply to each day of the week.
1. REFRIGERANT PIPES
Service Ref. : PKH-1.6GKL / PKH-2GKL
: PKH-1.6GKLH / PKH-2GKLH
Note 1. How to connect refrigerant pipes.
Factory supplied optional refrigerant pipings contain refrigerant at the above atmospheric pressures. As long as the
connection takes no more than minutes, no air will enter, and there will be no need for air purging. Remove the blind
caps and make the connections within minutes. After the connections for the indoor and outdoor units are made,
open the stop valve on the outdoor unit to allow refrigerant gas to flow.
If piping length exceeds 0m, an additional charge of refrigerant is needed.
Note 2. The following main parts are contained in the optional refrigerant piping kit.
Heat insulating cover, vinyl tapes, nipples, sleeve and flange (for wall hole).
2. TIMER
When using a program timer, PAC-SC2PTA, a program timer adapter (PAC-82AD) is also needed.
2-1 Program timer specifications
Part No
Pipe length
Pipe size O.D.
Connection method
PAC-05FFS-E
PAC-07FFS-E
PAC-10FFS-E
PAC-15FFS-E
5
"
7
"
15
"
10
"
Liquid:
W
9.52 Gas:
W
15.88
Indoor unit:Flared Outdoor unit:Flared
Service Ref.
Part No
Model Name
PKH-1.6/2GKL
PKH-1.6/2GKLH
PAC-SC32PTA(with set back function)
Program timer
Exterior dimensions (inch)
Installation
Type of clock
Clock accuracy
Display-Time
-Week
-Timer setting unit
Program cycle
Timer setting unit
No.of set points
Power rating
Set back function
Part No.
Part name
Service Ref.
Program timer
PKH-1.6/2GKL
PKH-1.6/2GKLH
PAC-SC32PTA
5-4/32 × 4-23/32 × 23/32(130×120×18
)
Wall mount
Quartz
50 seconds/month at 25
Liquid crystal display
Liquid crystal display
Liquid crystal display
24 hours
30 minutes
48/day
5V DC 5%(Supplyed by Remote Controller)
Provided
28
°
C
26
°
C
8:00
Normal
operation
23:00
Setback
operation
8:00
Normal
operation
OC229A