8~9 Refer to page 26~27.
w
12
When room temperature is 18°C or below, the compressor cannot operate.
When room temperature rises over 18°C, the compressor starts after a -minute time delay.
w
1
Compressor ON time is decided by room temperature. Refer to page 26~27.
w
1
In dry operation, compressor ON makes the fan speed LOW. Also, when the compressor OFF and the pipe tempera-
ture is 26°C or less, the fan stops, or when the compressor OFF and the pipe temperature is below 6°C, the fan speed
changes to LOW mode.
It is not possible to set the fan speed with the remote controller
DRY OPERATION
DRY
operation
Four-way valve / OFF
Initial dry
operation
Room temperature is
18°C or lower
During
compressor ON
Compressor &
thermostat ON
Vane initial setting
Vane
setting notch
10-minute compressor
OFF timer start
Compressor OFF
Fan STOP
-minute
time delay
10-minute
compressor
OFF
Compressor ON
time set
Compressor ON
Fan speed LOW
1
Compressor &
thermostat
ON
-minute
compressor
operation
Compressor ON
time completes
NO
YES
NO
NO
YES
w
1
w
1
w
1
YES
YES
NO
YES
NO
NO
w
9
YES
YES
w
9
NO
NO
w
12
YES
NO
YES
w
8
OC229A