<Before test run>
Measure an impedance between the power supply terminal block
on the outdoor unit and the ground with a 500 V Megger and
check that it is equal or greater than 1.0M
"
.
1
Turn on the main power to the unit.
2
Set the Nrm/Set selector switch (on the back of the controller) to <Set>.
A
The FUNCTION , TEST RUN and CHECK begin to blink.
3
Press the MIN. button.
B
TEST RUN and current operation mode are displayed.
4
Press the MODE button to activate COOL
mode, then check
whether cool air in blown out from the unit.
5
Press the
FAN
button and check whether strong air is
blown out from the unit.
5
Press the
VANE
button and check whether the auto vane oper-
ates properly.
7
Press the ON/OFF button to stop the test run.
8
After trial run is complete, set the Nrm/Set selector switch to <Nrm.>
Note :
·
Point the remote controller toward the inside unit’s receiver
while steps
3
though
7
.
·
It is not possible to run the unit in FAN or DRY mode.
<How to operate>
1
Press the ON/OFF button to turn it ON.
2
Press the STOP or START button (TIMER SET).
·
Time can be set while the following symbol is displayed.
OFF timer :
A
,
B
is displayed.
ON timer :
A
,
B
is displayed.
3
Use the HR. and MIN. buttons to set the desired time.
4
Cancelling the timer.
To cancel the OFF timer, press the STOP button.
To cancel the ON timer, press the START button.
·
It is possible to combine both OFF and ON timers.
·
Pressing the ON/OFF button of the remote controller during
timer mode to stop the unit will cancel the timers.
▼
▼
ON/OFF
CHECK
ADDRESS
UNIT No.
FUNCTION No.
SELECTION No.
AM
PM
RESET
AM
PM
TEST RUN
FUNCTION
°C
MODE
FAN
VANE
TEMP.
START
STOP
HR.
MIN.
A
B
1
24
3
ON/OFF
CHECK
ADDRESS
UNIT No.
FUNCTION No.
SELECTION No.
AM
PM
RESET
AM
PM
TEST RUN
FUNCTION
°C
MODE
FAN
VANE
TEMP.
START
STOP
HR.
MIN.
BA
7
3
5
4
6
82
OC229A