 Warning:

• 

Do not splash water over the unit and do not touch the unit with wet 
hands. An electric shock may result.

• 

Do not spray combustible gas close to the unit. Fire may result.

• 

Do not place a gas heater or any other open-fl ame appliance where it will 
be exposed to the air discharged from the unit. Incomplete combustion 
may result.

 Warning:

• 

Do not remove the front panel or the fan guard from the outdoor unit when 
it is running. You could be injured if you touch rotating, hot or high-voltage 
parts.

• 

Never insert fi ngers, sticks etc. into the intakes or outlets, otherwise injury 
may result, since the fan inside the unit rotates at high speed. Exercise 
particular care when children are present.

• 

If you detect odd smells, stop using the unit, turn off the power switch 
and consult your dealer. Otherwise, a breakdown, electric shock or fi re 
may result.

• 

When you notice exceptionally abnormal noise or vibration, stop opera-
tion, turn off the power switch, and contact your dealer.

• 

Do not over-cool. The most suitable inside temperature is one that is 
within 5 °C of the outside temperature.

• 

Do not leave handicapped people or infants sitting or standing in the path of 
the airfl ow from the air-conditioner. This could cause health problems.

 Caution:

• 

Do not direct the airfl ow at plants or caged pets.

• 

Ventilate the room frequently. If the unit is operated continuously in a 
closed room for a long period of time, the air will become stale.

In case of failure

 Warning:

• 

Never remodel the air conditioner. Consult your dealer for any repair or service. 
Improper repair work can result in water leakage, electric shock, fi re, etc. 

• 

If the remote controller displays an error indication, the air conditioner 
does not run, or there is any abnormality, stop operation and contact your 
dealer. Leaving the unit as it is under such conditions can result in fi re 
or failure. 

• 

If the power breaker is frequently activated, get in touch with your dealer. 
Leaving it as it is can result in fi re or failure.

• 

If the refrigeration gas blows out or leaks, stop the operation of the air 
conditioner, thoroughly ventilate the room, and contact your dealer. Leav-
ing the unit as it is can result in accidents due to oxygen defi ciency.

When the air conditioner is not to be used for a long 

time

• 

If the air conditioner is not to be used for a long time due to a seasonal 
change, etc., run it for 4 - 5 hours with the air blowing until the inside is 
completely dry. Failing to do so can result in the growth of unhygienic, 
unhealthy mold in scattered areas throughout the room.

• 

When it is not to be used for an extended time, keep the [power supply] 
turned OFF.

 

If the power supply is kept on, several watts or several tens of watts will 
be wasted. Also, the accumulation of dust, etc., can result in fi re.

• 

Keep the power switched ON for more than 12 hours before starting 
operation. Do not turn the power supply OFF during seasons of heavy 
use. Doing so can result in failure.

1.3.  Disposing of the unit

 Warning:

When you need to dispose of the unit, consult your dealer. If pipes are removed 
incorrectly, refrigerant (fl uorocarbon gas) may blow out and come into contact 
with your skin, causing injury. Releasing refrigerant into the atmosphere also 
damages the environment.

2. Names and functions of various parts

Attachment and detachment of fi lter

[Fig. A] (P.4)

3. How to operate

Before starting operation

• 

Start running after the “PLEASE WAIT” display has disappeared. The “PLEASE 
WAIT” display briefl y appears on the room temperature display (max. 3 minutes) 
when the power is turned on and after a power failure. This does not indicate 
any failure of the air-conditioner.

• 

The choice of indoor unit operation mode is limited by the operation status of 
the outdoor unit to which a given indoor unit is connected. If an outdoor unit and 
some of the indoor units that are connected to the outdoor units are already 
operating in the cooling mode, for example, only the cooling mode is available 
for the rest of the units in the same group. If a different mode is requested, the 
symbol that corresponds to the requested mode will blink, notifying the user 
that the mode is currently unavailable. The same is true for the dry and heating 
mode. This restriction, however, does not apply to the models that support a 
simultaneous cooling/heating function.

• 

The outdoor units stop when all the indoor units connected to the counterpart 
outdoor units stop.

• 

During heating operation, even if the indoor unit is set to operation while the 
outdoor unit is in defrosting operation, operation starts after the defrosting 
operation of the outdoor unit has ended.

3.1. ON/OFF

Start an operation

1. Press 

the 

B

 [ON/OFF] button

 

P

 Operation lamp lights up and operation starts.

Stop an operation

1.

 

Press the 

B

 [ON/OFF] button again

 

Operation lamp goes off and operation stops.

• 

Once the Buttons have been set, pressing of the [ON/OFF] Button only can 
repeat the same operation thereafter. 

• 

During operation, the operation lamp above the [ON/OFF] button lights up.

 Caution:

Even if the [ON/OFF] Button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of
approximately 3 minutes.

3.2. Selecting 

operation

When selecting operation

1. Press 

the 

3

 

[Mode (BACK)] Button

 

Consecutive press of the selecting operation Button switches the operation 
over to 

E

 “

COOL”, “ DRY”, “

FAN”, (“

AUTO”), and (“

HEAT”). For 

the contents of operation, check the display.

For cooling

Press the 

3

 [Mode (BACK)] Button and bring up the “

COOL

” display.

For dry

Press the 

3

 [Mode (BACK)] Button and bring up the “

DRY

” display.

• 

The indoor fan turns to the low-speed operation, disabling the change of fan 
speed.

• 

Dry operation cannot be carried out at room  temperature of less than 18 °C 
[65 °F].

 Caution:

• 

In removing the fi lter, precautions must be taken to protect your eyes from 
dust. Also, if you have to climb up on a stool to do the job, be careful not 
to fall.

• 

Turn off the power supply when the fi lter is changed.

ON/OFF 

CHECK

CLEAR

MENU

ON/OFF

TEST

TEMP.

CLOCK

OPERATION

BACK

DAY

MONITOR/SET

1

E

2

3

6 8

B

P

7

FILTER

ERROR CODE

TIME

ON

OFF

Hr

AFTER

SUN

MON TUE WED THU

FRI

SAT

TIMER

AFTER

ONLY 1Hr.

˚C

˚F

WEEKLY

SIMPLE

AUTO OFF

FILTER

FUNCTION

˚C

˚F

WT06599X01.indb   6

WT06599X01.indb   6

3/23/2012   5:22:06 PM

3/23/2012   5:22:06 PM

Summary of Contents for PEFY-P06NMAU-E2

Page 1: ...F OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuil...

Page 2: ...OFF FILTER CHECK CLEAR MENU ON OFF TEST TEMP CLOCK OPERATION BACK DAY MONITOR SET 1 2 3 4 D 5 6 8 9 C 0 A B 7 Remote controller Button Touche Commande distance GB F 1 Touche R glage de la temp rature...

Page 3: ...i ce N R glage des ailettes O Vitesse du ventilateur P T moin de fonctionnement Remote controller Display Affichage Commande distance GB F A Current time Timer time B Centralized control indicator C T...

Page 4: ...4 4 2 In case of bottom inlet En cas d entr e sur le dessous 1 In case of rear inlet En cas d entr e arri re A Filter Filtre Air Flow Flux d air A 1 A 2 Fig A...

Page 5: ...se of the wrong type of refrigerant 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand...

Page 6: ...t consult your dealer If pipes are removed incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also dama...

Page 7: ...n according to the change of the room temperature and automatically repeat ON OFF 2 When reaching room temperature of your choice Both the compressor and indoor fan stop When stop continues for 10 min...

Page 8: ...Heating operation starts after ending defrosting operation It runs briefly but soon stops The CHECK and check code flashes on the liquid crystal display There are some obstacles at the air inlet and o...

Page 9: ...the professional engineering work required for transferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in ele...

Page 10: ...he operating noise is the data that was obtained in an anechoic room Item Model P36NMAU E2 P48NMAU E2 P54NMAU E2 Power source 208 230V 60Hz Cooling capacity 1 Heating capacity 1 Btu h 36 000 40 000 48...

Page 11: ...e r frig rant 1 Appareil ext rieur Avertissement L appareil ext rieur doit tre install sur une surface plane et stable dans un endroit non sujet l accumulation de neige de feuilles ou de d tritus Ne p...

Page 12: ...ment Lorsque vous devez ranger l appareil veuillez consulter votre revendeur Si les tuyaux ne sont pas correctement retir s du produit r frig rant gaz fluorocarbonique pourrait s chapper et entrer en...

Page 13: ...arr t ON OFF 2 Lorsque la temp rature de votre choix est atteinte le compresseur et le ven tilateur int rieur s arr tent tous deux Si l arr t dure plus de 10 minutes le compresseur et le ventilateur i...

Page 14: ...in e Le climatiseur fonctionne pendant un bref instant puis s arr te aussit t Le code et la mention de v rification CONTROLE clignotent sur l affichage cristaux liquides Des obstacles bloquent l arriv...

Page 15: ...lez prendre contact au pr alable avec le revendeur pour une estimation du co t des travaux requis pour le d m na gement de l installation Pr caution Lors du d m nagement et de la r installation du cli...