1. Safety precautions

'

  Before installing the unit, make sure you read all the “Safety precautions”. 

'

  Please report to or take consent by the supply authority before connec-

tion to the system. 

'

 Equipment complying with IEC/EN 61000-3-12

    (PUHZ-HRP71/100VHA2)

'

 PUHZ-HRP200YKA

   “This equipment complies with IEC 61000-3-12 provided that the short-

circuit power S

sc

 

is greater than or equal to S

sc

 (*1) at the interface point 

between the user’s supply and the public system. It is the responsibility 
of the installer or user of the equipment to ensure, by consulation with 
the  distribution  network  operator  if  necessary,  that  the  equipment  is 
connected only to a supply with a short-circuit power S

sc

 greater than or 

equal to S

sc

 (*1)”

     S

sc

 (*1)

Model

S

sc 

(MVA)

PUHZ-HRP200YKA

1.35

After installation work has been completed, explain the “Safety Precautions,” use, 
and  maintenance  of  the  unit  to  the  customer  according  to  the  information  in  the 
Operation Manual and perform the test run to ensure normal operation. Both the 
Installation Manual and Operation Manual must be given to the user for keeping. 
These manuals must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels af

Þ

 xed to the main unit.

 Warning:

•   The unit must not be installed by the user. Ask a dealer or an authorized 

technician to install the unit. If the unit is installed incorrectly, water leak-
age, electric shock, or 

Þ

 re may result.

•   For installation work, follow the instructions in the Installation Manual and 

use tools and pipe components speci

Þ

 cally made for use with R410A re-

frigerant. The R410A refrigerant in the HFC system is pressurized 1.6 times 
the pressure of usual refrigerants. If pipe components not designed for 
R410A refrigerant are used and the unit is not installed correctly, the pipes 
may burst and cause damage or injuries. In addition, water leakage, elec-
tric shock, or 

Þ

 re may result.

•   The unit must be installed according to the instructions in order to mini-

mize the risk of damage from earthquakes, typhoons, or strong winds. An 
incorrectly installed unit may fall down and cause damage or injuries.

•   The  unit  must  be  securely  installed  on  a  structure  that  can  sustain  its 

weight. If the unit is mounted on an unstable structure, it may fall down 
and cause damage or injuries.

•   If the air conditioner is installed in a small room, measures must be taken 

to prevent the refrigerant concentration in the room from exceeding the 
safety limit in the event of refrigerant leakage. Consult a dealer regarding 
the appropriate measures to prevent the allowable concentration from be-
ing exceeded. Should the refrigerant leak and cause the concentration limit 
to be exceeded, hazards due to lack of oxygen in the room may result.

•   Ventilate the room if refrigerant leaks during operation. If refrigerant comes 

into contact with a 

ß

 ame, poisonous gases will be released.

•   All electric work must be performed by a quali

Þ

 ed technician according to 

local regulations and the instructions given in this manual. The units must 
be powered by dedicated power lines and the correct voltage and circuit 
breakers must be used. Power lines with insuf

Þ

 cient capacity or incorrect 

electrical work may result in electric shock or 

Þ

 re.

•   Use  C1220  copper  phosphorus,  for  copper  and  copper  alloy  seamless 

pipes, to connect the refrigerant pipes. If the pipes are not connected cor-
rectly, the unit will not be properly grounded and electric shock may result.

•   Use only speci

Þ

 ed cables for wiring. The connections must be made se-

curely without tension on the terminals. If the cables are connected or 
installed incorrectly, overheating or 

Þ

 re may result.

•   The terminal block cover panel of the outdoor unit must be 

Þ

 rmly attached. 

If the cover panel is mounted incorrectly and dust and moisture enter the 
unit, electric shock or 

Þ

 re may result.

•   When installing or moving the air conditioner, use only the speci

Þ

 ed refrig-

erant (R410A) to charge the refrigerant lines. Do not mix it with any other 
refrigerant and do not allow air to remain in the lines. Air enclosed in the 
lines can cause pressure peaks resulting in a rupture and other hazards.

•   Use only accessories authorized by Mitsubishi Electric and ask a dealer 

or an authorized technician to install them. If accessories are incorrectly 
installed, water leakage, electric shock, or 

Þ

 re may result.

•   Do not alter the unit. Consult a dealer for repairs. If alterations or repairs 

are not performed correctly, water leakage, electric shock, or 

Þ

 re may re-

sult.

•   The user should never attempt to repair the unit or transfer it to another 

location. If the unit is installed incorrectly, water leakage, electric shock, 
or 

Þ

 re may result. If the air conditioner must be repaired or moved, ask a 

dealer or an authorized technician.

•   After installation has been completed, check for refrigerant leaks. If refrig-

erant leaks into the room and comes into contact with the 

ß

 ame of a heater 

or portable cooking range, poisonous gases will be released.

1.1. Before installation 

 Caution:

•   Do not use the unit in an unusual environment. If the air conditioner is 

installed in areas exposed to steam, volatile oil (including machine oil), or 
sulfuric gas, areas exposed to high salt content such as the seaside, or 
areas where the unit will be covered by snow, the performance can be sig-
ni

Þ

 cantly reduced and the internal parts can be damaged.

•   Do not install the unit where combustible gases may leak, be produced, 

ß

 ow, or accumulate. If combustible gas accumulates around the unit, 

Þ

 re 

or explosion may result.

 Warning:

Describes precautions that must be observed to prevent danger of injury or 
death to the user.

 Caution:

Describes precautions that must be observed to prevent damage to the unit.

•   The outdoor unit produces condensation during the heating operation. 

Make sure to provide drainage around the outdoor unit if such condensa-
tion is likely to cause damage.

•   When installing the unit in a hospital or communications office, be pre-

pared for noise and electronic interference. Inverters, home appliances, 
high-frequency medical equipment, and radio communications equipment 
can cause the air conditioner to malfunction or breakdown. The air con-
ditioner may also affect medical equipment, disturbing medical care, and 
communications equipment, harming the screen display quality.

Note: This symbol mark is for EU countries only.
This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV.

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
Please, dispose of this equipment at your local community waste collection/recycling centre.
In the European Union there are separate collection systems for used electrical and electronic product.
Please, help us to conserve the environment we live in!

     Caution:
• Do not vent R410A into the Atmosphere:
• R410A is a Fluorinated Greenhouse gas, covered by the Kyoto Protocol, with a Global Warming Potential (GWP)=1975.

1. Safety precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
2. Installation location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
3. Installing the outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5
4. Installing the refrigerant piping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5
5. Drainage piping work. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9

6. Electrical work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
7. Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
8. Initial settings for refrigerant leakage detection function . . . . . . . . . . . . . . . . . .  11
9. Special Functions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
10. System control (Fig. 10-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

01̲RG79D564H02̲EN.indd   2

2009/08/26   8:33:54

Summary of Contents for Mr. Slim PUHZ-HRP-HA2

Page 1: ...ees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het installeren van de airconditioner begint MANUAL DE INSTALACI N Para un uso correcto y seguro...

Page 2: ...ctly overheating or re may result The terminal block cover panel of the outdoor unit must be rmly attached If the cover panel is mounted incorrectly and dust and moisture enter the unit electric shock...

Page 3: ...uch the pipes burns or frostbite may result After stopping operation be sure to wait at least ve minutes before turn ing off the main power switch Otherwise water leakage or breakdown may result 1 5 U...

Page 4: ...e space as shown Do not install the optional air outlet guides for upward air ow 3 Obstacles at front only Fig 2 14 When using the optional air outlet guides the clearance is 1000 mm or more 4 Obstacl...

Page 5: ...ible Vent Max 30 Set deep in the ground 600 600 Min 360 175 175 Min 10 950 25 330 370 4 Installing the refrigerant piping 4 1 Precautions for devices that use R410A refrigerant Refer to 1 5 for precau...

Page 6: ...C Local piping without oxygen 2 Connect the E Joint pipe to the gas side Stop valve Use 2 wrenches to tighten the are nut If order is reversed refrigerant leak occurs because of the part damaging by...

Page 7: ...to its original position Refrigerant pipes are protectively wrapped The pipes can be protectively wrapped up to a diameter of 90 before or after connecting the pipes Cut out the knockout in the pipe...

Page 8: ...The existing pipe thickness does not meet speci cations or the pipes are damaged Fig 4 9 Indoor unit Outdoor unit Main piping Branch piping Multi distribution pipe option Outdoor unit HRP200 A 9 52 65...

Page 9: ...efrigerant piping HRP71 100 125 HRP200 Drain socket PAC SG61DS E Drain pan PAC SG64DP E PAC SH97DP E 5 Drainage piping work Outdoor unit drainage pipe connection When drain piping is necessary use the...

Page 10: ...ire which is longer than the other cords so that it will not become disconnected when tension is applied A Control Outdoor Unit 3 poles isolator Power supply Isolator A Control Indoor Unit Warning In...

Page 11: ...operation Starting operation immediately after turning on the main power switch can result in severe damage to internal parts Keep the power switch turned on during the operational season The followi...

Page 12: ...the unit is stopped How ever even if the unit is stopped and the SWP switch is set to ON less than three minutes after the compressor stops the refrigerant collecting operation cannot be performed Wai...

Page 13: ...door unit C Master remote controller D Subordinate remote controller E Standard 1 1 Refrigerant address 00 F Simultaneous twin Refrigerant address 01 G Simultaneous triple Refrigerant address 02 E SW...

Reviews: