5.9. Receiving IP AlarmNotify of the recorder
With the DX-PC200, you can be notified of occurrences of events on the PC by utilizing IP
AlarmNotify from the recorder. In addition, you can confirm the event on a displayed list and
search for the recorder image at the corresponding time as required.
In order to utilize this function, you need to add a setting to the recorder so that IP AlarmNotify
is performed. The DX-PC200 can receive and display IP Alarm Notification without specific
setting. Setting to delete unnecessary IP AlarmNotify items is also possible.
5.9.1
Setting IP AlarmNotify of the recorder
As for a recorder to enable IP AlarmNotify, you can set a menu as a part of network setting.
Major items which require setting are as follows:
・
IP address of the PC which issued IP AlarmNotify: Several receivers of IP AlarmNotify
can be set in the major models of recorders.
・
Receiving port of the PC which issued IP AlarmNotify: Except for special occasion, you
are recommended to use the default value. In order to change this value, you need to
change the receiving port setting (refer to the following section) of the receiver PC.
・
Item of AlarmNotify: Sorting of items and the number of items are determined by the
recorder model. For detailed information, refer to the recorder instruction manual or
contact our distributor.
・
Retry interval: Set time intervals for retry.
In principle, setting is required only for IP address to issue IP AlarmNotify and notified items.
However, some recorder models require other setting items. In addition, setting the default
gateway is also required if a network is different.
5.9.2
Setting IP AlarmNotify receiving filter and alarm sound
When the DX-PC200 is installed, the receiving module (DataManager) resides permanently in
the task tray. The icon for the receiving module is shown below.
Right-clicking the task tray icon and clicking “AlarmNotify Setting” of the menu, you can open
the setting panel for receiving. When “Exit” is selected, the receiving module exits, and neither
content display nor list registration is performed even if AlarmNotify is received. When you
need to make the receiving module reside permanently, start the DX-PC200 and click the
DataManager button in the lower section of the MainView screen or the SingleView screen.