50
-
Model (Indoor)
Operation Mode
Automatic
High
Medium
Low
Hi power
Econo
5 ~ 25
5 ~ 25
5 ~ 18
5 ~ 12
25
5 ~ 18
5 ~ 46 (5~ 42)
5 ~ 46 (5~ 42)
5 ~ 32
5 ~ 19
42
5 ~ 32
7 ~ 59
7 ~ 59
7 ~ 42
7 ~ 24
59
7 ~ 42
7 ~ 64
7 ~ 64
7 ~ 47
7 ~ 27
64
7 ~ 47
25
35
50
60
(rps)
(3)
Operation of major functional components in cooling mode
Functional
components
Operation
Command speed
Indoor
unit fan
Compressor
Outdoor unit fan
Electronic
expansion valve
See preceding table
ON
According to command speed
According to outdoor unit speed
According to decision
speed
0
(All indoor units)
OFF
According to stop mode
According to mode switching
OFF
0
(Thermostat off units)
ON
All closed
(Thermostat off units)
According to outdoor unit speed
According to mode switching
All closed
(Fan, stop, abnormal stop units)
0
(Fan, stop, abnormal stop units)
0
(All units)
ON
According to command speed
OFF
OFF
According to stop mode
Cooling
Thermostat OFF
(All indoor units)
Thermostat OFF
(Some of indoor units)
Fan, stop, abnormal stop
(Some of indoor units)
Failure
(Outdoor unit)
Fixed
Automatic
Note (1) Values in ( ) are for type SRRM.
Model (Indoor)
Operation Mode
Automatic
High
Medium
Low
Hi power
Econo
7 ~ 28
7 ~ 28
7 ~ 22
7 ~ 15
28
7 ~ 22
7 ~ 29
7 ~ 29
7 ~ 24
7 ~ 15
29
7 ~ 24
7 ~ 34
7 ~ 34
7 ~ 26
7 ~ 16
30
7 ~ 26
7 ~ 41
7 ~ 41
7 ~ 27
7 ~ 17
32
7 ~ 27
22
7 ~ 27
7 ~ 27
7 ~ 21
7 ~ 15
27
7 ~ 21
20
25
28
35
9 ~ 61
9 ~ 61
9 ~ 32
9 ~ 18
51
9 ~ 32
50
(rps)
Model (Indoor)
Operation Mode
Automatic
High
Medium
Low
Hi power
Econo
7 ~ 33
7 ~ 33
7 ~ 25
7 ~ 16
33
7 ~ 25
7 ~ 62 (7~ 56)
7 ~ 62 (7 ~ 56)
7 ~ 44
7 ~ 26
56
7 ~ 44
9 ~ 79
9 ~ 79
9 ~ 56
9 ~ 32
79
9 ~ 56
9 ~ 85
9~ 85
9 ~ 63
9 ~ 36
85
9 ~ 63
25
35
50
60
(rps)
◆
STM, SRRM models
◆
STM, SRRM models
Note (1) Values in ( ) are for type SRRM.
(d) SCM80ZF-S
◆
SKM model